19
PROBLEM
PROBABLE CAUSE
REMEDY
a.
Damaged door gasket.
b.
Clogged compartment
drain or plumbing.
a.
Check gasket for cuts and
replace if necessary.
b.
Remove screen and clean
drain line or plumbing.
Water flows into cooking
compartment.
a.
Level control has failed.
b.
Water has very high
resistance. (i.e. low
mineral content or Reverse
Osmosis Water).
c.
Scale build-up on probe.
d.
Water fill solenoid valve.
a.
Replace.
b.
Replace level control with
high sensitivity control.
c.
Clean all probes in steam
generator.
d.
Plugged, defective, clean
or replace.
Water accumulates in
compartment.
a.
Plugged compartment
drain.
a.
Remove screen and clean
drain line.
Water flows into drain during
shutdown.
a.
Cooling valve does not
close.
a.
Check valve for foreign
material or damage.