5. Troubleshooting
(continued)
5-2
TROUBLE POSSIBLE CAUSE REMEDY
Generator will not create steam
(continued)
8. Faulty heaters.
8. Check/replace heaters.
9. Wiring short.
9. Check wiring at terminals.
10. No water in generator.
10. Add 2 gallons of water.
Generator continues to create
steam when the cooking
compartment door is
opened.
1. Faulty magnet reed switch (contacts
failed closed).
1. Check magnetic reed switch Replace
).
11. Faulty exhaust valve..
11. Check/replace exhaust valve (P/N 08-
4952).
12. Faulty preheat thermostat.
12. Check/replace preheat thermostat (P/
13. Faulty pressure switch.
13. Check/replace w.c. pressure switch
(P/N’s
&
2. Wiring short..
2. Checking wiring at terminals.
Generator dosen’t drain when
the drain valve is opened.
1. Clogged or kinked generator drain
line.
1. Check to be sure that the generator
drain line is not kinked and is free of
debris.
2. Clogged generator drain hole.
2. Check to be sure the generator drain
hole is free of debris.
Steamer fails to hold.
1. Faulty hold thermostat.
1. Replace (P/N
2. Faulty contactor.
2. Replace (P/N
2. Faulty timer.