INSTRUCTIONS FOR USER
If you have questions concerning the use of your boiler or heating system, please ask your installer. It is in
your own interest and that of the installer that you are aware of how to operate your boiler and heating
system safely and efficiently.
The appliance is not to be used by children or persons with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge.
Children, even if being supervised, must not play with the appliance
In the case of failure or malfunction of the appliance, do not attempt to repair it yourself.
Please contact your installer. Repairs must only be carried out by qualified technicians. Failure to
comply with these requirements can compromise the safety of the appliance.
Operation
Water, coming from the radiators or from the DHW unit is heated in the aluminium heat exchanger. The
CH or DHW pump guarantees circulation of water. The air needed for combustion is sucked in by a rpm
controlled fan. At low boiler temperatures the flue gases can be cooled sufficiently for condensation of
the water. This water is drained to the sewer via a built in syphon. This drainage must never be blocked. A
burner controller with built in micro processor provides the electrical control of the boiler.
Topping up
The built in manometer indicates if the waterpressure is sufficient. As soon as the water pressure drops
below 1 bar topping up is necessary. If topping up becomes a regular ocurrance, your installation should
be checked by an installer.
Disconnect from the main. Connect the filling hose to the cold water tap and to the fill and drain valve
of the boiler. Before tightning the coupling in the installation slowly fill the hose with water allowing any
air present to escape. Open the fill and drain valve and slowly fill the installation until a pressure between
1.5 and 2.0 bar is reached. When finished connect again to the main.
Bleeding
To remove any air present in the heating system and boiler, bleeding is necessary. Disconnect from the
main. Open all the radiator valves. Bleed the air from all the radiators starting with the ones at the
lowest point in the system. After bleeding, check the water pressure and top-up if required (if water
pressure has dropped below 1 bar). Connect to the main again.
Starting the boiler
Please ask your installer how to start the boiler. Depending on how your heating system is controlled,
this could be via an external timeclock, thermostat, switch or otherwise. Once the boiler volt-free enable
contacts are closed, the boiler will commence its starting sequence.
Boiler flow temperature
The burner controller can adjust the flow temperature between 20 ° and 85 °C. The temperature setting
can be changed using the control panel.
The installation manual provides the instructions for setting the flow temperature.
DHW (Hot Water) temperature ( if applicable)
From the factory, the DHW temperature is set to a value of 60 °C. This set value can be changed to any
value between 35 and 65 °C using the buttons on the control panel. If the DHW device has a thermostat
the DHW temperature can be adjusted by setting this thermostat.