____________________________________________________________
CLMD16 Configuration Guide Rev.1.1 51
Step 2
:
Arrange the ECB parameters. For the ECB used as the speed control output to the motor, set
the ECB to “PWM” type with the appropriate “Counter Element” assigned to the ECB. Ensure
“Toggle Mode” is On for this ECB. Set the ECB parameters for the windshield wiper “Park”
signal
choosing an available “Logic Element” as the “Input Signal”. Ensure “Toggle Mode” is
Off for this ECB. Because the ECB used for the “Park” signal should not be influenced by any
outside signals turn “Manual Mode” on for this ECB.
Step 3
:
Add the “Park” signal Logic. Where “0” is Off and “1” is On, configure the “Logic Output” in a
manner where the “Logic Output” will always be On when the ECB used for the speed control
is Off.