CLMD16 Configuration Guide___________________________________
14 CLMD16 Configuration Guide Rev.1.1
Configurating Tank Level Inputs
The CLMD16 is able to broadcast up to three instances of tank level data via NMEA 2000®
127505 PGN. The following dialog(s) explain the parameters that will need to be configured for
the tank level broadcast.
By clicking on “Tank Levels Calibration” another dialog box will appear. See the following
dialog depiction to understand how to enter the calibration data. Please note the tank level
calibrations are not saved with the CLMD16 device’s overall configuration file but instead, the
CLMD16 has the ability to save each tank level channel’s calibration to individual files. This is
not done automatically when the CLMD16’s configuration is saved as the configurator will need
to save tank calibration data files separately.
Содержание MPOWER CLMD16
Страница 4: ...This Page Intentionally Left Blank...
Страница 15: ...____________________________________________________________ CLMD16 Configuration Guide Rev 1 1 11...
Страница 42: ...CLMD16 Configuration Guide___________________________________ 38 CLMD16 Configuration Guide Rev 1 1...
Страница 58: ......