22
www.marchetti.eu
RI
• It is mandatory to keep a distance of at least 5.00 metres from power line;
• Once moved, engage the brakes on the four wheels, level the tower again and move the stabilizers
until perfectly in contact with the ground.
VERIFICATION, CARE AND MAINTENANCE
• After a certain number of uses, at the discretion of the operator, clean away the encrustations of
cement, mortar, paint or other which will eventually build up on the various components;
• Always keep the supplied clamping and adjusting screws, and the gudgeon/wrist pins and couplings
of the various couplers well oiled;
• Before every assembly, check that all components are in perfect condition, replacing any damaged or
worn components with others of the same type, which must be original components as indicated by
the manufacturer;
• While moving, transporting or storing the mobile access tower, take care to not subject any of its
components to loads which could cause permanent deformation, avoiding therefore badly organised
stacking and stacking together with materials of a different nature.
•Storage in a covered and sheltered place is recommended to reduce damage due to corrosion over
time.
USE ACCORDING TO D.LGS. 81/08
• All the mobile access towers pursuant to D.Lgs. 81/08, but not to EN 1004 standard, must be anchored
to a fixed stable structure every two levels.
• They can also have only one working platform fitted, complete with toeboards and guardrails.
• Guardrails can be D.Lgs. 81/08 composed of n° 2 steel bracing elements with blocking device at the
two parts. If guardrails are D.Lgs. 81/08 working platforms need to be placed attentively, in order to
have the tower lateral bracing element (upper guardrail) at a minimum of m 1.00 distant from working
platform and insert bracing element of guardrails in a intermediate position between upper guardrail
and toeboard.
• Work platform can also be mounted in positions such as to have the rod as an upper parapet and a
tower beam as an intermediate parapet, always respecting the mutual distances mentioned above.
• Mobile towers compliant with Legislative Decree 81/08, must have the wheels of the base braked
during use and positioned on a perfectly leveled floor.
• The extractable feet, when present, are removed by the maximum quantity compatible with the
surrounding dimensions: pull the extractables up to the MAX line.