PDxx01
RS-232C Control Specification
Page: 46 / 49
Document Version [1.0]
Company Restricted
5-73.
POWER ON MODE (VOLUME)
Function
Power-on modes (Volume) are set up.
Transmission Data
DFH 80H 60H 0FH 01H DATA00 CKS
DATA00: Power ON mode (VOLUME)
A0H:
LAST
00H:
volume0
:
2A H: volume42
ACK
7FH 60H 80H 0FH 00H CKS
5-74.
74. SUB PICTURE RATE set
Function
Sub screen rate of PIP are set up.
Transmission Data
DFH 80H 60H DAH 02H DATA00 DATA01 CKS
DATA00: Sub screen rate Gain flag
01H
DATA01: Sub screen rate Gain
00H: 20%
01H: 30%
02H:
40%
03H:
50%
04H: 60%
05H:
70%
06H:
80%
07H: 90%
08H:
100%
DATA02:
FADE
00H:
NORMAL
01H: FADE
ACK
7FH 60H 80H DAH 01H DATA00 CKS
DATA00: Sub screen rate Gain flag
01H