PDxx01
RS-232C Control Specification
Page: 10 / 49
Document Version [1.0]
Company Restricted
5-7.
CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: CONTRAST Gain Flag
07H
DATA02: CONTRAST Gain
CCH: -52
:
FFH:
-01
00H:
0
01H:
+01
:
14H:
+20
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: CONTRAST Gain Flag
07H
5-8.
BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BRIGHT Gain Flag
08H
DATA02: BRIGHT Gain
E0H: -32
:
FFH:
-01
00H:
0
01H:
+01
:
20H:
+32
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BRIGHT Gain Flag
08H