PDxx01
RS-232C Control Specification
Page: 42 / 49
Document Version [1.0]
Company Restricted
ACK
7FH 60H 80H 3CH 01H DATA00 CKS
DATA00
00H:
OFF
01H: CC1 (closed caption1)
02H: CC2 (closed caption2)
03H: CC3 (closed caption3)
04H: CC4 (closed caption4)
05H:
TEXT1
06H:
TEXT2
07H:
TEXT3
08H:
TEXT4
5-64.
CC (Closed caption) CONTRAST SELECT
Function
External control apparatus selects the Closed Caption Contrast function of a plasma monitor.
Transmission Data
DFH 80H 60H 3DH 01H DATA00 CKS
DATA00
01H:
NORMAL
02H:
LOW
ACK
7FH 60H 80H 3DH 01H DATA00 CKS
DATA00
01H:
NORMAL
02H:
LOW
5-65.
PICTURE MEMORY Select
Function
The external control equipment selects the Picture Memory function of a plasma monitor.
Transmission Data
DFH 80H 60H 38H 01H DATA00 CKS
DATA00: MEMORY select
00H: OFF
01H:
MEMORY1
02H:
MEMORY2
03H:
MEMORY3
04H:
MEMORY4
05H:
MEMORY5
06H:
MEMORY6
ACK
The plasma monitor returns the following ACK when the input is switched.
7FH 60H 80H 38H 01H CKS
DATA00:
00H:
OFF
01H:
MEMORY1
02H:
MEMORY2
03H:
MEMORY3
04H:
MEMORY4
05H:
MEMORY5
06H:
MEMORY6