PDxx01
RS-232C Control Specification
Page: 19 / 49
Document Version [1.0]
Company Restricted
5-26.
AUTO PICTURE Select
Function
The external control equipment switches on or off the AUTO PICTURE of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: AUTO PICTURE Select
Flag
09H
DATA02
00H:
ON
01H:
OFF
ACK
7FH 60H 80H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: AUTO PICTURE Select
Flag
09H
DATA02
00H:
ON
01H:
OFF
5-27.
PHASE (FINE PICTURE) Gain Data
Function
The external control equipment changes the PHASE gain data (Phase) of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: PHASE Gain Flag
03H
DATA02: PHASE Gain
00H: 0
:
40H: +64 :
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: PHASE Gain Flag
03H