PDxx01
RS-232C Control Specification
Page: 43 / 49
Document Version [1.0]
Company Restricted
5-66.
PICTURE MEMORY Set
Function
The external control equipment ser and reset the Picture Memory function of a plasma monitor.
Transmission Data
DFH 80H 60H 25H 02H DATA00 DATA01 CKS
DATA00:
01H:
SET
02H:
RESET
DATA01: MEMORY select
00H: OFF
01H:
MEMORY1
02H:
MEMORY2
03H:
MEMORY3
04H:
MEMORY4
05H:
MEMORY5
06H:
MEMORY6
ACK
The plasma monitor returns the following ACK when the input is switched.
7FH 60H 80H 25H 01H CKS
DATA00:
01H:
SET
02H:
RESET
5-67.
PICTURE MEMORY NOTE WRITE Set
Function
External control apparatus writes to NOTE of PICTURE MEMORY o
f a plasma display.
Transmission Data
DFH 80H 60H 2DH 0FH DATA00 to DATA14 CKS
Even DATA00-DATA14 is set up as follows.
Setting value
00H-09H
: 0 - 9
80H
: - (Hyphen)
81H :
+
82H :
83H :
/
84H :
(
85H :
)
86H :
.
87H :
‘
96H : Blank
10H-29H: A-Z of Alphabet
NOTE: When “PICTURE MEMORY” selects “OFF”, this command is no support.