Designed in Italy Assembled in China
From the “Input” Page all the available processes on the Input Path can be available for editing without the
Input Page Processes
On the Input path the available processes are the following:
Noise Gate:
In the signal path, the first process which is found by the signal is the Noise Gate.
The Noise Gate process can be made active or skipped through the Noise Gate check-box
If the Noise Gate is selected, then the parameters for setting it will be active in the Noise Gate frame.
Within the “Noise Gate” frame, the Main parameters of the Noise Gate process can be set:
Threshold: is representing the Threshold of the Noise Gate activation.
If the averaged peak of the Input Signal is remaining below this threshold, the
Noise Gate become active; thresholds are available from -50dBu up to -80dBu
with steps of -5dBu.
Release Time: is representing the “speed” in exiting the Gated signal condition,
when detected a Input Signal Peak exceeding the Threshold level.
Available Release Times are going from 10ms up to 1sec.
Attack Time: is representing the “speed” in Entering the Gated signal condition,
when detected an averaged Input Signal Peak bellowing the Threshold level.
Available Attack Times are going from 0.5sec up to 1sec.
PDA500P User Manual