Designed in Italy Assembled in China
SETUP:
pressing the SETUP button, it is possible to decide the operative mode of the PDA500P
LOCK:
The LOCK Button, when pressed, is opening a window requiring a Password for entering the Output
pages or/and the Main Compression/Limiting Page.
Particularly, if pressed the LOCK button and provided the Password =
OUTPUT
(not case sensitive), the
Output Pages will be available for editing and they will be selectable from button that will appear on the top bar
The PDA500P can work both in SE 2 Ways mode, providing 2x500W/4Ohm, or in BTL mode, where working in
bridge mode can deliver 1kW/8Ohm on a mono output .
Depending from the selected Operative Mode, the Output Editing pages will differ and in case of the BTL mode,
they will be grouped in just one set of processes and the DSP will automatically create the outputs for the
DPA500P to work in BTL mode (see the Editing Output Pages in 2Ways and BTL Mode paragraph).
and again pressing the LOCK button and provided the Password =
LIMCMP
(not case sensitive), the Main
Compression/Limiting Page will be available for editing and will be selectable from button that will appear on the
top bar
In all the above cases, when Unlocked the Output or/and Master Compression/Limiting pages, the pages can be
entered just pressing the related button on the top bar.
NOTE: when using the PDA500P in Bridge Mode, please foolow the Pascal Audio S-PRO2
setting indications for the S-PRO2 Amplifier Module Output setting.
More, need to Ground the Pin 10 of the DSP I/O board connector if wanted to use the
PDA500P in Bridge mode driving a 4 Ohm Load.
PDA500P User Manual