38
Montage- und Betriebsanleitung
Installation and Operating Instructions
EN
W
WAARRN
NIIN
NG
G
RRiisskk ooff iinnjjuurryy dduuee ttoo eexxpplloossiioonn oorr m
maatteerriiaallss sshhoooottiinngg oouutt ooff tthhee sshhrriinnkk cchhuucckk dduurriinngg tthhee sshhrriinnkkiinngg pprroocceessss!!
When heating during the shrinking process, closed liquid-filled areas, such as cooling channel bores, can lead to the ex-
plosion of the shrink chuck or to the loosening of the shank from the location bore. This can lead to severe injuries and
burns.
Before the shrinking process, empty the cooling channel bores and open the closed areas.
Only carry out the shrinking process in rooms in which any escaping combustion gases can be safely discharged.
33..55..22
M
Meecchhaanniiccaall hhaazzaarrddss
W
WAARRN
NIIN
NG
G
RRiisskk ooff iinnjjuurryy dduuee ttoo ddaam
maaggee ttoo tthhee ttooooll sshhaannkk oorr llooccaattiioonn bboorree ooff tthhee sshhrriinnkk cchhuucckk!!
Damage to the tool shank or the location bore of the shrink chuck can cause the tool to come loose during machining
and cause injuries and damage to the workpiece.
Check tool and shrink chuck for damage before the shrinking process.
W
WAARRN
NIIN
NG
G
CCllaam
mppiinngg aanndd uunnccllaam
mppiinngg w
wiitthh rruunnnniinngg m
maacchhiinnee!!
Clamping and unclamping the shrink chuck with the machine running may result in serious injuries to the operator.
Actuate the shrink chuck only off the machine and with the machine at a standstill.
Montage- und Betriebsanleitung
Installation and Operating Instructions
39
EN
N
NOOTTEE
TTooooll lleennggtthh aaddjjuussttm
meenntt w
wiitthh tthhee ttooooll ccllaam
mppeedd!!
Performing an axial tool length adjustment while the tool is completely clamped will result in damage to the shrink
chuck.
Do not change the tool length adjustment as long as the tool is clamped.
N
NOOTTEE
U
Ussee ooff sshhaannkkss w
wiitthh rreecceesssseess!!
Use of shanks with Form B and E (DIN 1835) or shanks with HB and HE (DIN 6535) can result in radial run-out errors and
inaccurate balancing value of the whole system.
Use only shanks with Form A or fine balance the whole system.
CCAAU
UTTIIO
ON
N
SShhaarrpp ccuuttttiinngg eeddggeess oonn tthhee ttooooll!!
Sharp cutting edges may cause cutting injuries.
Wear protective gloves when changing tools.
Montage- und Betriebsanleitung
Installation and Operating Instructions
39
EN
Содержание ThermoChuck
Страница 1: ...Montage und Betriebsanleitung Installation and Operating Instructions Schrumpffutter Shrink chuck ...
Страница 2: ......
Страница 62: ......