Mantracourt Electronics Limited
T24 Technical Manual
58
UseCSMA
18
Select whether to use
Carrier Sense Multiple Access
techniques on transmission
.
Value
Description
0
Disabled
The
Carrier Sense Multiple Access
will be
disabled.
NOT RECOMMENDED
1
Enabled
The
Carrier Sense Multiple Access
will be
enabled.
See
Unslotted CSMA/CA
in
Appendix A
UINT8
RW
Reset
54
Restarts the device and utilises new channel and
encryption keys if those have been changed and saved.
Note after a Reset the device will be asleep.
Command
Save
55
Save any changes made to parameters. Required before
power cycling or issuing a Reset command.
Requires 500mS recovery time after executing.
Command
DoPrint
129
Trigger an output (Print). Note that the outputs will not
trigger at a rate faster than the interval set by MinInterval.
Command
DoSySZero
98
Perform a system zero on all devices. This will remove the
current input values so from this point on the current input
will give a value of zero. This can be removed by issuing
the RmSysZero command.
Command
RmSySZero
99
Reset the system zero settings so values will represent the
actual inputs.
Command
Value1
60
Read or write the value used as input 1 which can be
represented with the <V1> token and is used in generating
the result (sum).
FLOAT
RW
Value2
61
Read or write the value used as input 2 which can be
represented with the <V2> token and is used in generating
the result (sum).
FLOAT
RW
Value3
62
Read or write the value used as input 3 which can be
represented with the <V3> token and is used in generating
the result (sum).
FLOAT
RW
Value4
63
Read or write the value used as input 4 which can be
represented with the <V4> token and is used in generating
the result (sum).
FLOAT
RW
Value5
64
Read or write the value used as input 5 which can be
represented with the <V5> token and is used in generating
the result (sum).
FLOAT
RW
Value6
65
Read or write the value used as input 6 which can be
represented with the <V6> token and is used in generating
the result (sum).
FLOAT
RW
Value7
66
Read or write the value used as input 7 which can be
represented with the <V7> token and is used in generating
the result (sum).
FLOAT
RW
Value8
67
Read or write the value used as input 8 which can be
represented with the <V8> token and is used in generating
the result (sum).
FLOAT
RW
Timeout1
100
Read or write the timeout in milliseconds. If the time
between receiving data from the device defined as input 1
(Set in ValueDataTag1) exceeds this value then the <V1>
token and any tokens using this value will result in '------'
instead of a real value.
UINT16
RW
Timeout2
101
Read or write the timeout in milliseconds. If the time
between receiving data from the device defined as input 2
(Set in ValueDataTag2) exceeds this value then the <V2>
token and any tokens using this value will result in '------'
instead of a real value.
UINT16
RW
Timeout3
102
Read or write the timeout in milliseconds. If the time
between receiving data from the device defined as input 3
(Set in ValueDataTag3) exceeds this value then the <V3>
token and any tokens using this value will result in '------'
instead of a real value.
UINT16
RW