Integrated treatment system with endodermic massage

and application of pulsed magnetic fields with stochastic resonance

MR991

Use and Maintenance Instructions

The manual must be kept in a safe place for the entire life of the machine. Please read carefully the 

manual before operating any part of the equipment

Includes CE Certificate of Conformity

Содержание MR991

Страница 1: ...alia it Integrated treatment system with endodermic massage and application of pulsed magnetic fields with stochastic resonance MR991 Use and Maintenance Instructions The manual must be kept in a safe place for the entire life of the machine Please read carefully the manual before operating any part of the equipment Includes CE Certificate of Conformity ...

Страница 2: ... 4 Connection for telecare if available 18 7 COMMISSIONING 19 7 1 Equipment functions 19 7 1 1 Maxi DES handpiece 19 7 1 2 Mini DES handpiece 19 7 1 3 Maxenergy handpiece 19 7 1 4 Vixo handpiece 19 7 2 Switching on and preparation of the equipment 19 7 3 Start a treatment cycle 22 7 3 1 Background information 22 7 3 2 First treatment cycle 22 7 3 3 Function control buttons on the handpieces see 4 ...

Страница 3: ...EMS 30 9 1 Accessories 30 9 2 Installation of accessories 30 9 2 1 Handpiece without PMF system Code MN50043 30 10 EQUIPMENT DECOMISSIONING 31 11 PROBLEMS AND SOLUTIONS 31 12 SPARE PARTS 32 13 GENERAL WARRANTY TERMS AND CONDITIONS 33 ...

Страница 4: ...bsequent amendments and additions Legislative Decree no 110 of 12 May 2011 and subsequent amendments also complies with the following directives 2004 108 CE Electromagnetic compatibility 2006 95 CE Low voltage complies with the following regulations CEI 62 39 Electrical equipment for the beauty industry General safety guide CEI EN 60601 1 third edition and subsequent amendments Electromedical equi...

Страница 5: ...rains the stagnant liquid in the tissue the CMPS system is ideal to treat lymphoedema and cellulite 1 2 Definitions and symbols used in the manual The manual includes some pictures which have been defined and authorised for use on the equipment according to different purposes Manufacturer the equipment producer who affixes his own distinctive brand on the equipment MANTIS s r l Operator the person...

Страница 6: ... face treatment on the recommended areas and following the specified procedure 2 2 Reasonably foreseeable misuse MR991 in any of its functions should not be used in the following cases People with implantable devices heart stimulators internal defibrillators etc Treatment on open wounds eyes body cavities nipples and testicles MR991 in MRM mode mechanical manipulation with motorised rollers should...

Страница 7: ...he treatment cycle the Customer s health conditions do not undergo any change which could be a contraindication for the treatment Under no circumstances should MR991 be used to treat people with implantable devices heart stimulators internal defibrillators etc Under no circumstances should MR991 be used to treat open wounds eyes body cavities nipples and testicles The Manufacturer will assume no r...

Страница 8: ...rking space required around the equipment 900 mm 35 43 in Power cable length 2 5 m 8 2 ft Working length of handpiece tubes 2 m 6 5 ft Degree of protection IP20 Degree of protection against direct and indirect contact BF type Insulation class 1 Power supply 230 V 2P E Frequency 50 60 Hz Circuit breaker 10 A Maximum power consumption 1200 W ...

Страница 9: ... 1 Touch screen control panel 2 Vixo handpiece 3 Maxi DES handpiece 4 Mini DES handpiece 5 Maxenergy handpiece 6 Key switch 7 Emergency stop 8 USB port 9 Wheels 10 Wheels with brake system 11 Carrying handles 9 2 3 1 4 5 6 7 10 9 9 8 11 11 ...

Страница 10: ...andpiece holder 22 Cable conduit cover 23 Handpiece connector cover 24 Ethernet connection 25 Main switch 26 Maxenergy connection 27 Electric power supply 28 Mini DES Maxi DES connections 29 Mini DES Maxi DES connections 30 Vixo connections 31 Filters 10 21 22 23 24 26 25 27 4 3 2 5 30 28 29 31 23 ...

Страница 11: ...dpiece B1 Start Pause B2 Higher function level B3 Backwards movement of rollers B4 Scrolling menu functions B5 Lower function level B6 Function display C Vixo handpiece C1 Start Pause D Maxenergy handpiece D1 Start Pause 11 A B C D A1 A1 B1 B2 B3 B4 B5 B3 C1 D1 D1 B6 ...

Страница 12: ...by unplugging the machine In case of maintenance disconnect the power supply by unplugging the machine at the rear Before carrying out any maintenance or cleaning operations such as the connection of handpieces the cleaning of filters etc always remember to disconnect the power supply by unplugging the machine Do not alter or tamper with the equipment s safety systems Do not install the machine ne...

Страница 13: ...rms for the detection of malfunctions Roller anti lock device Handpiece connector mechanical locking device Equipment front wheel brake system 5 3 Pictograms On the equipment near the main switch and on the handpiece holder you will find some pictograms displaying the safety requirements as well as the CE marking If the stickers become illegible they must be replaced CE marking and plate data 2 Da...

Страница 14: ...t to damage the outside wrapping 2 Remove the tape on the upper part of the package 3 Remove the whole wrapping by sliding it upwards 4 Check that all three parts A B C are inside the package and that they are not damaged 5 Take out packages A and B 6 Remove protecting film C without using any sharp objects 7 Unscrew the two blocking knobs D at the base of MR991 8 Check packages A and B which must...

Страница 15: ...ation Your working area must be wide enough to be able to carry out all the necessary manoeuvres both while working and while carrying out routine maintenance and cleaning see technical data The wheels make small movements easy However for the positioning of the equipment the surrounding area must have a diameter of at least 0 9 m 2 95 ft Do not forget to take into account the length of the power ...

Страница 16: ... knob of the cable conduit cover was fixed 22P 4 Reinsert and tighten the screws which were previously removed in order to assemble the transparent handpiece holder 21 5 Reassemble the cable conduit cover by fixing it with the knob again 22P 6 Disassemble the lower cover 23 by pulling gently and insert the LED power connector into the socket 31 7 Insert the Vixo connector case into the supplied ro...

Страница 17: ...he suction hose in the appropriate places 32 and 35 Insert the hose by applying some pressure in order to ensure that it works properly Insert the connector and lock it by pulling the lower lever IThe Maxi DES and Mini DES handpiece connections are interchangeable If needed it is possible to invert the connections without altering the equipment s functioning 22 Make sure that the filter caps are i...

Страница 18: ...k answer from the Technical Assistance Staff thereby considerably reducing any downtime periods of the equipment In order to be able to take advantage of the telecare you need to have a DSL line a modem and a socket for the connection of the Ethernet cable optional Connect the Ethernet cable to the appropriate socket 24 near the main switch 24 18 ...

Страница 19: ...axenergy handpiece Maxenergy is completely based on a powerful CMPS system which is able to carry out a shock therapy on the layers of subcutaneous fat It can also be used to apply the special magneto catalysed Mantis Magnetic Cream which has a deeper penetration effect thanks to the ionic channels created on the skin by CMPS 7 1 4 Vixo handpiece The Vixo handpiece consists of a microsuction syste...

Страница 20: ... quoting the code written under chapter 12 Spare Parts The LEDs on the transparent handpiece holder will turn on 4 After a short self test during which the equipment monitors the proper functioning of the handpieces the touch screen control panel displays menu A Press Enter to access the following menu B 5 From menu B select Settings to enter the next menu and set the necessary parameters to guara...

Страница 21: ...select Language from menu C otherwise skip to step 8 7 From menu D select the appropriate language and click Forward 8 From menu C select Date and Time to access the corresponding settings E and use the arrows to adjust the parameters Click Forward 21 C D E ...

Страница 22: ...he type of treatment available from that menu After selecting the desired treatment press Forward to enter the next menu NB MR991 automatically identifies and controls the functioning of the connected handpieces In the event of malfunctions or connection problems the function or functions related to the handpiece where the problem was detected should be disabled on the touch screen DES Technology ...

Страница 23: ...ble from menu G by selecting the item Drenax Notice that each procedure is accompanied by step by step instructions In order to change the settings if necessary the professional mode can be accessed from any DES Technology automatic treatment To begin the treatment it is necessary to press the START button on the c o r r e s p o n d i n g handpiece By pressing the STOP button the treatment can be ...

Страница 24: ...de the PMF technology colour grey for inactive PMFs and colour green for active PMFs Begin the treatment by selecting START on the touch screen and then START on the c o r r e s p o n d i n g handpiece 7 Menu N is accessible from menu F by selecting the item Vixo The Vixo treatment for body and décolleté consists of two phases step 1 and step 2 The first phase employs the PMF technology with sucti...

Страница 25: ...touch screen Then press START on the Vixo handpiece It is possible to interrupt the ongoing treatment at any time by pressing the STOP button on the handpiece Pause It is possible to interrupt the ongoing treatment at any time by pressing the PAUSE button or STOP button which will reset the time on the touch screen From any menu you can return to the previous one by clicking on BACK Save all data ...

Страница 26: ... by pressing one of the two buttons for 1 second To reverse the rollers direction press one of the buttons for 2 seconds To deactivate pause the handpiece quickly press one of the buttons Maxenergy handpiece On the Maxenergy handpiece there are two identical START STOP control buttons The handpiece can be activated by pressing one of the two buttons for 1 second while it can be deactivated pause b...

Страница 27: ...he START button on the touch screen and the START STOP button on the handpiece for 1 second By pressing the STOP button on the touch screen while a treatment is in progress the timer is reset to zero 7 6 Equipment emergency stop All equipment functions can be immediately stopped at any time by pressing the emergency stop button which is located under the touch screen control panel of the machine s...

Страница 28: ...carried out by the Technical Assistance 8 1 1 Cleaning and disinfection of the handpieces Maxi DES and Mini DES Pull the tabs out using the provided tool Clean them with a cloth moistened with a solution formed by 90 of water and 10 of a disinfectant product containing sodium hypochlorite e g Amukine Use the same solution to clean the rollers and the handpiece contact surface area Do not use any p...

Страница 29: ...move the filter caps 31 by turning them anti clockwise 3 Take the cartridges out 4 Clean the cartridges and caps by means of a vacuum cleaner Do not use water or liquid cleansers that could damage the vacuum pump Every 100 hours of equipment operation or when indicated on the touch screen replace the filter cartridges 5 Put the cartridges back into the caps and reassemble them turning them clockwi...

Страница 30: ... be used with the machine and after the treatment CA40032 Handpiece without PMF system MN50043 Switch key 2 pieces 032 482 9 2 Installation of accessories 9 2 1 Handpiece without PMF system Code MN50043 The handpiece without PMF system works in the same way as the other handpieces but being lighter it is smoother and more manageable The handpiece is installed in place of the Mini DES and used with...

Страница 31: ...Technical Assistance No flashing light on LED when the Maxenergy handpiece should be active Connector not inserted properly or damaged Insert connector see par 6 4 2 Assembly or replace if damaged see par Spare Parts Damaged software Contact Technical Assistance No flashing light on LED when the Vixo handpiece should be active Damaged software Insert connector see par 6 4 2 Assembly or replace if ...

Страница 32: ...Filters FT10010 2 Handpiece tabs LM11020 3 Switch keys 032 482 4 Mini DES handpiece MP13040 5 Maxi DES handpiece MP13041 6 Maxenergy handpiece MX16030 7 Vixo handpiece VX17020 8 Power cable CA14050 9 Tab removal tool CM10723 32 3 6 4 7 5 8 1 2 9 ...

Страница 33: ...y therefore covers exclusively manufacturing defects and non conformity of the product Any component subject to natural wear and tear shall always be excluded from the Warranty The warranty shall not apply in case of tampering repair and or alteration carried out by non authorised people The warranty shall not apply in case of damages caused by accidents electrical malfunctions on the power supply...