H. PRODUCT FICHE 

 

This product contains a self-cleaning backward curved impeller that requires no servicing.

 

 
 

Name:  

Manrose 

Manrose 

Model ID (Stock Ref.) : 

MANI3000N 

MANI3000N 

SEC Class 

SEC Value ('Average') 

-26.25 

-18.87 

SEC Value ('Warm') 

-10.75 

-6.85 

SEC Value ('Cold') 

-53.31 

-39.84 

Label Required? (Yes/No=Out of scope) 

Yes 

Yes 

Declared as: RVU or NRVU/UVU or BVU 

RVU  

RVU  

Speed Drive 

Multi-Speed 

Multi-Speed 

Type HRS (Recuperative, Regenerative, None) 

None  

None  

Thermal Eff: [ (%), NA(if none)] 

N/A  

N/A  

Max. Flow Rate (m3/h) 

396.00 

396.00 

Max. Power Input (W): (@Max.Flow Rate) 

63.30 

63.30 

LWA: Sound Power Level (dB) 

51.53 

51.53 

Ref. Flow Rate (m3/s) 

0.08 

0.08 

Ref. Pressure Diff. (Pa) 

TBC 

TBC 

SPI [W/(m3/h)] 

0.12 

0.12 

Control Factor & Control Typology: (CTRL/ Typology) 

  

  

Control Factor; CTRL 

0.65 

0.85 

Control Typology 

Local Demand 

Control 

Central Demand 

Control 

Declared: -Max Internal & External Leakage Rates(%) for BVUs or 
carry over (for regenerative heat exchangers only),                                      
-&Ext. Leakage Rates (%) for Ducted UVUs; 

<5% Internal, <5% 

External 

<5% Internal, <5% 

External 

Mixing Rate of Non-Ducted BVUs not intended to be equipped 
with one duct connection on either supply or extract air side; 

N/A 

N/A 

Position and description of visual filter warning for RVUs 
intended for use with filters, including text pointing out the 
importance of regular filter changes for performance and energy 
efficiency of the unit 

N/A 

N/A 

For UVUs (Instructions Install Regulated Supply/Extract Grilles 
Façade) 

In F&W 

In F&W 

Internet Address (for Disassembly Instructions) 

www.manrose.co.uk 

www.manrose.co.uk 

Sensitivity p. Var20/-20 Pa: (for Non-Ducted Vus) 

N/A 

N/A 

Air Tightness-ID/OD-(m3/h) (for Non-Ducted Vus) 

N/A 

N/A 

Annual Electricity Consumption: AEC (kWh/a) 

0.82 

1.23 

Annual Heating Saved: AHS (kWh/a) 

  

  

AHS: Average 

28.30 

21.93 

AHS: Warm 

12.80 

9.92 

AHS: Cold 

55.36 

42.90 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
476875A 

 

 

 

 

 

 

 

 

 

 

 

 

0817 

Содержание MANI3000N

Страница 1: ...PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Watt Manivent AC Whole house extract system Installation and Wiring Instructions MANI3000N IP22...

Страница 2: ...an s rating label 6 When the fan extracts air from a room containing an open flue of a gas or fuel burning appliance precautions must be taken to avoid the back flow of gases into the room 7 The fan s...

Страница 3: ...he other remaining LS input can be used to switch the unit to Purge speed B SITING DO NOT install this product in areas where the following may be present or occur Excessive oil or a grease laden atmo...

Страница 4: ...t diameter The larger the better Avoid having any bends filters or other obstructions within 250mm of the fan inlets and outlet 1 Position the MANI3000N taking into consideration the position of the r...

Страница 5: ...less than 3mm Cable clamps are provided for use with the cable or flex on entry into the MANI3000N The MANI3000N has three speed settings Select the required speed and wire as indicated in Figure 1 Al...

Страница 6: ...6 Fig 2 Wiring for 3 speeds selectable by external switch Fig 3 Wiring for automatic switching from medium to high speed utilising an external sensor...

Страница 7: ...ny obstruction leave for a short time for the motor to cool before reconnecting If this recurs Isolate the MANI3000N and call a service engineer F COMMISSIONING Select the speed needed based on the si...

Страница 8: ...Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External 5 Internal 5 External...

Отзывы: