  Installation and Wiring Instructions for the ManiVent MANI3000N. 

 

     IMPORTANT: 
     READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION 

 
 
 

SAFETY AND GUIDANCE NOTES 

 
1. DO NOT install this product in areas where the following may be present or occur: 
1.1. Excessive oil or a grease laden atmosphere. 
1.2. Corrosive or flammable gases, liquids or vapours. 
1.3. Ambient temperatures higher than 40°C or less than -5°C. 
1.4. Possible obstructions which would hinder access or removal of the Fan. 
2. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country and 
MUST be installed by a suitably qualified person. 
3. The fan should be provided with a 3A fused, isolator switch capable of disconnecting all poles, having a contact 
separation of at least 3mm. 
4. Ensure that the mains supply (voltage, frequency, and phase) complies with the fan’s rating label. 
6. When the fan extracts air from a room containing an open flue of a gas or fuel burning appliance, precautions 
must be taken to avoid the back-flow of gases into the room. 
7. The fan should not be used where it is liable to be subjected to direct water spray. 
8. The fan should be mounted at the highest point in the system to protect it from condensation build up. 
9. This fan should be vented to the outdoors. 
10. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety. 
11. Children should be supervised to ensure that they do not play with the appliance. 
12. PLEASE NOTE: Some older fluorescent and low energy lighting products can interfere with other 
electronic/timing circuits. For reliable operation of timers use post 2000 low energy bulbs or tungsten filament bulbs 
in the room lighting circuit. 

 
TYPICAL INSTALLATION

 

 

Содержание MANI3000N

Страница 1: ...PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Watt Manivent AC Whole house extract system Installation and Wiring Instructions MANI3000N IP22...

Страница 2: ...an s rating label 6 When the fan extracts air from a room containing an open flue of a gas or fuel burning appliance precautions must be taken to avoid the back flow of gases into the room 7 The fan s...

Страница 3: ...he other remaining LS input can be used to switch the unit to Purge speed B SITING DO NOT install this product in areas where the following may be present or occur Excessive oil or a grease laden atmo...

Страница 4: ...t diameter The larger the better Avoid having any bends filters or other obstructions within 250mm of the fan inlets and outlet 1 Position the MANI3000N taking into consideration the position of the r...

Страница 5: ...less than 3mm Cable clamps are provided for use with the cable or flex on entry into the MANI3000N The MANI3000N has three speed settings Select the required speed and wire as indicated in Figure 1 Al...

Страница 6: ...6 Fig 2 Wiring for 3 speeds selectable by external switch Fig 3 Wiring for automatic switching from medium to high speed utilising an external sensor...

Страница 7: ...ny obstruction leave for a short time for the motor to cool before reconnecting If this recurs Isolate the MANI3000N and call a service engineer F COMMISSIONING Select the speed needed based on the si...

Страница 8: ...Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External 5 Internal 5 External...

Отзывы: