47
The On/Off button must be depressed and the ice
damper must be closed before the ice machine will start.
Water Purge Cycle
The ice machine purges any remaining water from the
water trough down the drain.
Freeze Cycle
Prechill - The refrigeration system chills the evaporator
before water flow over the evaporator starts. The water
inlet valve energizes during the pre-chill and remains on
until the ice thickness float switch is satisfied.
Freeze - Water flowing across the evaporator cools as
the freeze cycle progresses. (Software version 2.58 or
higher: The water pump turns off for 25 seconds and the
water inlet valve energizes for 7 seconds when the pump
restarts) Water flowing across the evaporator will start to
freeze and build ice on the evaporator. After a sheet of ice
has formed, the harvest float switch signals the control
board to start a harvest cycle.
Harvest Cycle
Any remaining water is purged down the drain as
refrigerant gas warms the evaporator. When the
evaporator warms, the sheet of cubes slides off the
evaporator and into the storage bin. If all cubes fall clear
of the ice damper the ice machine starts another freeze
cycle. The maximum harvest time is a total of 7 minutes.
If the bin switch does not activate within 3.5 minutes, the
harvest cycle extends another 3.5 minutes.
Full Bin Cycle
If the ice damper is held open by ice cubes the ice
machine shuts off. When the ice damper closes the ice
machine starts a new cycle at the water purge.
Содержание STH042 4/16
Страница 2: ......
Страница 14: ...14 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 42: ...42 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 56: ...56 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 98: ...98 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 124: ...124 Part Number STH042 4 16 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING SV1406 Using Pinch Off Tool ...
Страница 126: ...126 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 136: ...136 Part Number STH042 4 16 U140 U190 U240 WIRING DIAGRAM WITHOUT J4 THERMISTOR TERMINAL ...
Страница 137: ...Part Number STH042 4 16 137 U310 WIRING DIAGRAM WITHOUT J4 THERMISTOR TERMINAL ...
Страница 138: ...138 Part Number STH042 4 16 U140 U190 U240 WIRING DIAGRAM WITH J4 THERMISTOR TERMINAL ...
Страница 139: ...Part Number STH042 4 16 139 U310 WIRING DIAGRAM WITH J4 THERMISTOR TERMINAL ...
Страница 144: ...144 Part Number STH042 4 16 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 145: ......