Installation Instructions
Section 2
2-24
Part Number 000002477 3/08
Step 5 Pressure Test and Evacuate The Line Set
and CVD Condensing Unit
Schrader valve core removal tools that allow for removal
and installation of the valve cores without removing
manifold gauge set hoses are recommended to
decrease the evacuation time.
Leave the line set shut off valves closed (front seated).
Pressure test the line sets and CVD condensing unit
with 150 psig of dry nitrogen. Add nitrogen at the line set
shut off valves located at the back of the ice machine.
Complete the pressure test, verify no leaks are present
and remove the nitrogen from the system before
connecting the vacuum pump. Connect a vacuum pump
to both of the line set shut off valves located at the back
of the ice machine head section. Evacuate to 500
microns (or less). To completely evacuate the CVD
condensing unit, continue the evacuation for 30 minutes
after reaching the 500 micron point.
If required, the line set and condensing unit can be
evacuated from the schrader valves located in the CVD
condensing unit. Schrader valve core removal tools (that
allow for putting the cores back in without removing
vacuum pump hoses) must be used if evacuating from
the condensing unit side.
Isolate the vacuum pump from the line set shut off
valves and/or condensing unit access ports prior to
proceeding. Open refrigeration system shut off valves.
The suction line, liquid line and receiver service valves
are closed during shipment and installation.
ALTERNATE CONNECTIONS AT
CONDENSING UNIT SCHRADER VALVES
SV2085
SV1769b
CONNECT
VACUUM PUMP TO
LINE SET SHUT
OFF VALVES
CONNECT
VACUUM PUMP TO
LINE SET SHUT
OFF VALVES
SV1757
SV1757
CVD1485 CONDENSING UNIT SCHRADER
VALVES
CVD1486
CONDENSING UNIT
SCHRADER VALVES
SV3081
Содержание S model
Страница 6: ...Table of Contents continued 4 Part Number 000002477 1 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...General Information Section 1 1 6 Part Number 000002477 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...Installation Instructions Section 2 2 34 Part Number 000002477 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 54: ...Ice Machine Operation Section 3 3 8 Part Number 000002477 3 08 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 57: ...Section 4 Maintenance Part Number 000002477 3 08 4 3 A B C D E F G ...
Страница 59: ...Section 4 Maintenance Part Number 000002477 3 08 4 5 A B C D F G E ...
Страница 61: ...Section 4 Maintenance Part Number 000002477 3 08 4 7 A B C E F D G H ...
Страница 71: ......