Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
•
The location must be free of airborne and other
contaminants.
•
The air temperature must be at least 50°F (14.4°C),
but must not exceed 100°F (37.8°C).
•
Remote air cooled - The air temperature must be at
least -20°F (-29°C), but must not exceed 120°F
(49°C).
•
The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
•
The location must not obstruct air flow through or
around the ice machine. Refer to the chart below for
clearance requirements.
•
Location must be indoors.
Clearance Requirements
The entire front of the ice machine must be clear of
obstructions/connections to allow removal.
* There is no minimum clearance required for water-cooled or remote
ice machines. This value is recommended for efficient operation and
servicing only.
Installation Requirements
•
The ice machine and bin must be level.
•
Run the ice machine and bin drains separately.
•
Bin drain termination must have an air gap.
•
The ice machine and bin must be sanitized after
installation.
•
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
•
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the
warranty.
RN0400
Self-Contained
Air-Cooled
Self-Contained
Water-Cooled
Back
5 in. (12.7 cm)
—
Sides/Top
8 in. (20.3 cm)
—
RN1000/RN1400
Self-Contained
Air-Cooled
Water-Cooled
and Remote*
Back
5 in. (12.7 cm)
5 in. (12.7 cm)
Sides/Top
8 in. (20.3 cm)
8 in. (20.3 cm)
!
Caution
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty.