Installation Instructions
Section 2
10
Part Number 000007282 4/10
Water Supply and Drain Line Sizing/Connections
The exact locations of inlets and drains for the model you are working on may vary
Typical Water Supply Drain Installation
!
Caution
Plumbing must conform to state and local codes.
Location
Water
Temperature
Water Pressure
Ice Machine Fitting
Tubing Size Up to Ice
Machine Fitting
Ice Making
Water Inlet
45°F (7.2°C) Min.
90°F (32.2°C) Max.
20 psig (138 kPa) Min.
70 psig (483 kPa) Max.
1/2 in. (1.27 cm) FPTs
1/4 in. (0.64 cm) min
inside diameter
Ice Making
Water Drain
—
—
3/4 in. (1.90 cm) Pipe Thread
3/4 in. (1.90 cm) min
inside diameter
Condenser
Water Inlet
90°F (32.2°C) Max.
Standard
20 psig (138 kPa) Min.
150 psig (1034 kPa) Max.
3/8 in. (0.95 cm) Female Pipe Thread
Condenser
Water Drain
—
—
3/8 in. (0.95 cm)
Female Pipe Thread
3/8 in. (0.95 cm) min
inside diameter
Bin Drain
—
—
3/4 in. (1.91 cm)
Female Pipe Thread
3/4 in. (1.91 cm) minimum
inside diameter
Large Capacity
Bin Drain
—
—
1 in. (2.54 cm) Male Pipe Thread
1 in. (2.54 cm) min. inside diameter
SEPERATE BIN AND
ICE MACHINE DRAINS
ARE REQUIRED.
ROUTE DRAIN
TUBING TO OPEN
SITE DRAIN.
WATER SHUT-OFF VALVE
REQUIRED ON RN0400 ONLY -
ICE MAKING WATER INLET
TUBING 3/8" MIN. I.D. (.95 CM)