2-8
Published 03-23-2018 Control # 243-14
SAFETY PRECAUTIONS
NBT50 OPERATOR MANUAL
NOTE:
This condition is limited to operation with the main
boom on fully extended outriggers only.
c) If
V(z)
is > 20.1 m/s (45 mph), then lifting is NOT
permitted. Cease lifting operations and lower and retract
the boom.
In both cases
a
) and
b
) above, the lift may also be limited by
the projected wind area of the load
Ap
and by the wind drag
coefficient
Cd
: This limit can be determined by comparing
the
Actual
wind resistance area with the
Allowable
wind
resistance area.
Refer to Figure 2-1 for a simplified calculation method to
determine permissible wind speed.