RATED CAPACITY LIMITER
NBT50 OPERATOR MANUAL
7-14
Published 03-23-2018 Control # 243-14
allowed but the maximum function speed will be decreased
according to the speed reduction.
Select function key 2 Tools on the MAIN Menu screen and
the Tools Screen will appear.
Select the Joystick Output Setup icon
to display
the Joystick Output Setup screen.
Joystick Output Setup
The Joystick Output Setup screen allows the operator to
select what percentage of maximum hydraulic valve spool
shift to use when operating the crane in “Crane Control”, this
function does NOT work in “Radio Remote Control”.
-
The top horizontal bar on the Joystick Output Setup
screen allows the operator to select all the crane
functions be set to either 100%, 75%, 50% or 30%.
-
The five vertical bars on the screen allow the
operator to select a range of either 30%, 50%, 75%,
or 100% for each function. Each function is
identified by the icon at the top of the vertical bar as
noted in the following table.
-
Yellow indicates the current setting.
-
Default value for the Joystick Output screen is all
values @ 100%, as shown in Joystick Output #2
screen.
Joystick Output #2
-
The operator can also set the desired output for
each function as shown in Joystick Output #3
screen.
Using the arrow keys select the new percentage
using the vertical bar. The new value will turn yellow
indicating it is the current value, Joystick Output #3
screen.
Joystick Output #3
-
When a Joystick value is not set at 100% (default
standard); the RCL Operating Mode screen
(page 7-4) will identify the non-standard setting in
the upper left hand corner next to the general error
icon.
-
Values are saved when the machine is shutdown.
RCL Sensor Calibration
The RCL sensors are located throughout the crane and are
used to monitor the lifting parameters set by the crane
operator. To be sure the sensors are working correctly it is
sometimes necessary to verify the calibration of each RCL
sensor. To perform this calibration:
Select key 2, Tools on the Main Menu.
The Tools Screen will appear, select the
icon, the
Main Sensor Calibration Menu will appear.
Swing Control Valve
Boom Telescoping Valve
Auxiliary Hoist Valve
Main Hoist Valve
Boom Lift Valve
7623-44
Содержание National Crane NBT50 Series
Страница 1: ...Operator Manual National Crane NBT50 Series ...
Страница 2: ......
Страница 10: ...TOC 6 TABLE OF CONTENTS OPERATOR MANUAL NBT50 THIS PAGE BLANK ...
Страница 12: ...INTRODUCTION OPERATOR MANUAL NBT50 1 2 Published 03 23 2018 Control 243 14 FIGURE 1 1 7650 66 ...
Страница 50: ...2 36 Published 03 23 2018 Control 243 14 SAFETY PRECAUTIONS NBT50 OPERATOR MANUAL 8496 1 FIGURE 2 6 ...
Страница 82: ...CONTROLS AND OPERATING PROCEDURES OPERATOR MANUAL NBT50 3 22 Published 03 23 2018 Control 243 14 FIGURE 3 14 ...
Страница 134: ...MAINTENANCE CHECKLIST OPERATOR MANUAL NBT50 6 12 Published 03 23 2018 Control 243 14 THIS PAGE BLANK ...
Страница 157: ......
Страница 158: ......