Part Number 020002365 08/25/2015 49
Section 5
Troubleshooting
E7, E8, & E9 Flowchart
EI
E2
E3
E4
E5
E6
E7
E8
E9
NORMALLY CAUSED BY CARB
MOTOR A RUNNING > 7
MINUTES CONTINUOUSLY
NORMALLY CAUSED BY ICE
ON ICE BANK PROBE PIN #2
(MIDDLE PIN)
SAME AS E8 FOR CARB
B MOTOR/PUMP
NO
YES
NO
NO
YES
YES
VERIFY VISUALLY THAT ICE
IS OVER ICE BANK PROBE
PIN #2 (MIDDLE PIN)
FIRST CHECK FOR LEAK IN
CARB SYSTEM
YES
NO
YES
NO
PIN #2
COVERED IN
ICE
LEAK IN
SYSTEM
VERIFY ICE BANK PROBE
INSTALLED
CORRECTLYPLASTIC STEP ON
PROBE AWAY FROM EVAP
FIX LEAK
UN-PLUG CARB B
CONNECTOR FROM ERC (#1)
TO VERIFY CONDUCTIVITY
OK
THEN CHECK FOR PUMP
OUTPUT(32 OZ IN LESS
THAN 20 SEC)
“E7” ERROR
GOES AWAY
PUMP GOOD
UN-PLUG ICE BANK PROBE
CONNECTOR (#3) FROM ERC
BOARD
RESET ERROR (PUSH CARB A
AND/OR B BUTTON OFF, THEN
ON TO RESET
COMPRESSOR ON TOO
LONGGOTO
COMPRESSOR /
REFRIGERATION
TROUBLESHOOTING
“E7” ERROR
GOES AWAY
IF “E8” AND/OR “E9”
CONTINUE TO OCCUR
REPLACE ERC CONTROL
BOARD 020001985
REPLACE ERC
CONTROL BOARD IF
PROBLEM CONTINUES
020001985
REPLACE ICE BANK
PROBE 020002091
REPLACE PUMP
Содержание Multiplex 42 MR04
Страница 8: ...8 Part Number 020002365 08 25 2015 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...44 Part Number 020002365 08 25 2015 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...50 Part Number 020002365 08 25 2015 Troubleshooting Section 5 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 51: ...Part Number 020002365 08 25 2015 51 Section 5 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...