Checklist
If a problem arises during operation of your post mix soda
refrigeration unit, follow the checklist below before calling
service. Routine adjustments and maintenance procedures
are not covered by the warranty.
n
Warning
Only trained and certified electrical and plumbing
technicians must service this unit. All wiring and
plumbing must conform to national and local codes.
Problem
Possible Cause
To Correct
Water only dispensing:
No pressure
Regulator(s) out of adjustment
Check/adjust regulator(s).
Out of CO
2
Install fresh tank.
Defective regulator(s)
Check/repair/replace regulator(s).
CO
2
line pinched, kinked, or obstructed
Check/repair/replace CO
2
line.
Syrup and CO
2
only dispensing:
Carbonator
No power
Check power supply. Plug in carbonator or
reset breaker.
Water supply
Make sure water is turned ON.
Replace water filter.
Check/clean/replace pump strainer.
Check/clean/repair water check valve.
Check for frozen water line.
Internal Carbonator unit only.
Defective carbonator
Check/repair/replace carbonator pump,
motor, electrode or liquid level control.
Syrup and plain water only dispensing:
No pressure
Out of CO
2
Install fresh tank.
HP regulator out of adjustment
Adjust HP regulator to the proper setting.
Defective HP regulator
Check/repair/replace HP regulator.
CO
2
line pinched, kinked, or obstructed
Check/repair/replace CO
2
line.
One valve will not dispense anything:
Is there power to the valve?
Broken wire or loose connection
Replace/repair wire or connector.
Bad microswitch
Replace microswitch.
Beverage dispensed is too sweet:
Is the ratio (brix) of the drink correct?
Flow control out of adjustment
Adjust the flow control.
Insufficient soda flow due to low carbonator
pressure
Adjust CO
2
pressure or change the tank.
Low CO
2
pressure due to leaks
Repair CO
2
leaks.
Obstruction in the water or soda line
Clean out the lines.
Beverage is not sweet enough:
Is the ratio (brix) of the drink correct?
Flow control out of adjustment
Adjust the flow control.
Soda flow too high
Reset CO
2
pressure or replace regulator if
necessary.
Obstruction in syrup line
Clean out the syrup line.
Drinks are foaming:
Are system pressures correct?
Over carbonation
Check CO
2
supply. Reset pressure or replace
regulator as necessary.
Dirty lines/valves
Clean and sanitize entire system.
Section 5
Troubleshooting
Содержание Multiplex 42 MR04
Страница 8: ...8 Part Number 020002365 08 25 2015 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...44 Part Number 020002365 08 25 2015 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 50: ...50 Part Number 020002365 08 25 2015 Troubleshooting Section 5 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 51: ...Part Number 020002365 08 25 2015 51 Section 5 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...