12 Replacing components
eikon e2s Service and Repair Manual UL
152
The outlet of the cooling duct carries heat to the back of the oven
and is covered by a grille.
The outlet comprises a sheet metal frame containing holes
corresponding to the positions of Pozidriv screws securing the
cooling duct to the magnetron.
Use these holes for guiding the Pozidriv screwdriver.
Tools required
Hammer or similar tool
PZ2 Pozidriv screwdriver
M8 hex socket wrench
Requirements
Check that the following requirements have been met:
The appliance has been disconnected from the power supply and protective measures have been
taken to ensure the power cannot be switched on again.
The appliance is cool.
The top, left and right panels of the casing of the appliance have been removed.
The high voltage capacitors are discharged before commencing work.
Anti-static precautions have been taken.