12 Replacing components
eikon e2s Service and Repair Manual UL
183
Cavity thermostat and cavity temperature sensor (thermocouple)
The cavity thermostat is located besides the cooling duct on the
left hand side of the oven (when looking at the oven from the
rear). It continuously measures the temperature in the cavity and
prevents the cavity from overheating.
Measuring is done by a temperature sensor (thermocouple)
which is essentially a wire extending between the cavity thermo-
stat and the interior of the cavity.
This temperature sensor wire runs along the left vertical edge of
the cavity being attached to the cavity insulation with
heat-resistant tape.
Transformer (low voltage)
The low voltage transformer is located besides the cooling duct
on the left hand side of the appliance.