10 Tests
eikon e2s Service and Repair Manual UL
112
If the temperature reading is unstable:
1.
Disconnect and isolate the appliance from the electricity supply.
Take protective measures to ensure the power cannot be switched on again.
2.
Allow the appliance to cool down.
3.
Remove the side and top panels of the casing.
4.
Check the cavity temperature sensor wire and connections.
5.
If the wire and connections are working properly replace the cavity temperature sensor (see “Replacing
components” section of this manual).
6.
Refit the panels of the casing.
Switch ON the appliance and repeat the test procedure as described above.
7.
If the temperature is still unstable repeat steps 1 to 3, replace the SRB (see “Replacing components”
section), repeat step 6.
NOTE: Reuse the existing PM (Personality Module) on the new SRB (enter serial number on reboot).
Soak test: checking the cavity integrity
1.
Place an oven/microwave safe container with approx. 2 litres of
water into the cavity.
2.
Close the appliance door and select ‘Soak Test’ from the Service
Mode oven tests (maximum oven temperature, 50% microwave
power, maximum fan speed).
3.
Run the test (30 minutes), carefully checking the appliance
casing, joints and door seal for signs of steam or water escaping
from the cavity.
4.
If necessary, rectify any leaks and repeat the test.
5.
Safely remove the container from the cavity.
Содержание Merrychef eikon e2s
Страница 138: ...12 Replacing components eikon e2s Service and Repair Manual UL 138 12 2 Overview View left hand side ...
Страница 139: ...12 Replacing components eikon e2s Service and Repair Manual UL 139 View right hand side ...
Страница 140: ...12 Replacing components eikon e2s Service and Repair Manual UL 140 View rear side ...
Страница 179: ...12 Replacing components eikon e2s Service and Repair Manual UL 179 ...
Страница 190: ...13 Circuit boards and diagrams eikon e2s Service and Repair Manual UL 190 ...