Part Number STH038 5/12
73
UPGRADING FIRMWARE WITH A FLASH DRIVE
OR TRANSFERRING SETUP DATA TO MULTIPLE
MACHINES
1. Drag and drop the files from your email onto a
flash drive or refer to Exporting data to a flash
drive to transfer settings to multiple machines.
2. Ensure that the ice machine’s power is on.
3. Press the Menu button.
4. Press the Down arrow until Service is highlighted.
5. Press the Checkmark. The Service menu will be
displayed.
6. Press the Down arrow until USB Setup is
highlighted.
7. Press the Checkmark. USB Stick will appear
highlighted.
8. Press the Checkmark again. A submenu with
Download Frm (Download Firmware) appears.
9. Ensure that Download Frm is highlighted and
press the Checkmark. A display of instructions will
appear.
Important
The flash drive must be formatted before using,
All files and software on the flash drive are
removed during the formatting process. Refer to
page 69 USB Flash Drive Specifications and
Formatting.
USB Setup
USB Stick
Download Frm
Содержание I0320A
Страница 20: ...18 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 26: ...24 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 86: ...84 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 124: ...122 Is the evaporator dirty Dry evaporator first then check YES NO NO ...
Страница 174: ...172 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 176: ...174 Part Number STH038 5 12 I0320 Self Contained 1 Ph ...
Страница 177: ...Part Number STH038 5 12 175 I0500 Self Contained 1 Ph ...
Страница 180: ...178 Part Number STH038 5 12 ...
Страница 181: ......