Part Number STH038 5/12
145
WATER WILL NOT RUN INTO THE SUMP TROUGH
DURING THE FREEZE CYCLE
Step 1
Verify water is supplied to the ice machine.
Step 2
Scroll to Service/Diagnostics/Inputs and press
down arrow until Wtr Low and Wtr High are displayed.
A. Yes is displayed - Control board is receiving a
sensing water signal. Proceed to step 3.
B. No is displayed - Control board is not
receiving a sensing water signal. Proceed to
Control Board Diagnostics page 124.
Step 3
Disconnect water level probe, observe LCD
display text.
A. No is displayed - Clean the water level probe
and test interconnecting wiring.
B. Yes is displayed - Refer to Control Board
Diagnostics page 124
Содержание I0320A
Страница 20: ...18 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 26: ...24 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 86: ...84 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 124: ...122 Is the evaporator dirty Dry evaporator first then check YES NO NO ...
Страница 174: ...172 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 176: ...174 Part Number STH038 5 12 I0320 Self Contained 1 Ph ...
Страница 177: ...Part Number STH038 5 12 175 I0500 Self Contained 1 Ph ...
Страница 180: ...178 Part Number STH038 5 12 ...
Страница 181: ......