68
Par
t Number
STH03
8 5/12
Event Log Detail
E-Log Display Text
Error Description
Definition
E01
Long Freeze
Long Freeze
6 consecutive 60 Minute Freeze cycles = shut down and flash the SL#1 light on board
E02
Long Harvest
Long Harvest
3 consecutive - 3.5 Minute Harvests logs SL#2 in memory, but runs until 500 long harvest cycles occur.
E03
Power Loss
Power Supply (Event Log only -
No Alarm)
When power is interrupted to the ice machine the control board will log the event in the ELOG and
stamp the loss of power on power-up.
E04
Hi Cnd Temp or
Wtr Cnd Fault
Air Condenser High temp, or
water Condenser High
temperature
1). Liquid Line Temperature too High for Self-contained Air Cooled Ice machine = Air Cooled
Condenser Fault
2). Liquid Line Temperature too High for Self-contained Water Cooled ice machine = Water Cooled
Condenser Fault
E05
HPC Fault
High Pressure Cutout (HPC)
The high pressure cutout switch (HPCO) opened
E06
Spare
E07
Starving TXV
Starving Evaporator for single
TXV or low on charge
10 consecutive occurrences where the Difference of the Average evaporator inlet (T3) and outlet (T4)
is greater than 12°F (ELOG-E07)
E08
TXV Fault
TXV malfunction in dual circuit/
single evaps (TXV Fault)
E09
Flood Evap 1
Flooding evaporator for single
circuit single evaporator (flooding
evap)
During the first 6 minutes of the freeze cycle, the compressor discharge line temperature average (T2)
fell below the average temperature of the 6 previous cycles.
E10
Flood Evap 2
Flooding evaporator for dual TXV
dual circuit / single evaporator
(Flooding Evap)
Detail Event Log Service Definition
10 consecutive occurrences where the Difference of the Average evaporator inlet (T3) and outlet (T4)
is greater than 12°F (ELOG-E07)
During the first 6 minutes of the freeze cycle, the compressor discharge line temperature average (T2)
fell below the average temperature of the 6 previous cycles.
Содержание I0320A
Страница 20: ...18 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 26: ...24 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 86: ...84 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 124: ...122 Is the evaporator dirty Dry evaporator first then check YES NO NO ...
Страница 174: ...172 Part Number STH038 5 12 This Page Intentionally Left Blank ...
Страница 176: ...174 Part Number STH038 5 12 I0320 Self Contained 1 Ph ...
Страница 177: ...Part Number STH038 5 12 175 I0500 Self Contained 1 Ph ...
Страница 180: ...178 Part Number STH038 5 12 ...
Страница 181: ......