![Manitowoc Grove TMS800E13 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/manitowoc/grove-tms800e13/grove-tms800e13_operators-manual_701232025.webp)
GROVE
2-9
TMS800E13 OPERATOR MANUAL
SAFETY INFORMATION
2
Published 02-06-2014, Control # 495-00
•
Ensure the load lines are directly over the attach points
to avoid side loading and transfer of loading from one
crane to the other.
•
Do not travel. Lift only from a stationary position.
ELECTROCUTION HAZARD
Thoroughly read, understand, and abide by all applicable
federal, state, and local regulations regarding operation of
cranes near electric power lines or equipment.
United States federal law prohibits the use of
cranes closer than 20 ft (6 m) to power sources
up to 350 kV and greater distances for higher
voltages unless the line’s voltage is known
[29CFR1910.180 and 29CFR1926, subpart CC].
To avoid death or serious injury, Manitowoc rec-
ommends that all parts of crane, boom, and
load be kept at least 20 ft (6 m) away from all
electrical power lines and equipment less than
350 kV.
NOTE:
For detailed guidelines on operating near power
lines, refer to the current edition of OSHA
29CFR1926, subpart CC and ASME B30.5
American National Standard.
If operation within 10 ft (3 m) of any power lines cannot be
avoided, the power utility
must
be notified and the power
lines
must
be de-energized and grounded
before
performing any work.
If contact is ever accidentally made with a power line and any
part of this crane, its rigging or load,
never
touch the crane or
even approach or come near the crane.
Electrocution
can occur
even without direct contact with the
crane.
Crane operation is dangerous when close to an energized
electrical power source. Exercise extreme caution and
prudent judgement. Operate slowly and cautiously when in
the vicinity of power lines.
Before operating this crane in the vicinity of electrical power
lines or equipment, notify the power utility company. Obtain
positive and absolute assurance that the power has been
turned off.
This crane is
not insulated
. Always consider all parts of the
load and the crane, including the wire rope, hoist cable,
pendant cables, and tag lines, as conductors. You, the
operator, are responsible for alerting all personnel of
dangers associated with electrical power lines and
equipment. Do not allow unnecessary personnel in the
vicinity of the crane while operating. Permit no one to lean
against or touch the crane. Permit no one, including riggers
and load handlers, to hold the load, load lines, tag lines, or
rigging gear.
WARNING
Electrocution Hazard!
Manitowoc cranes are not equipped with all features
required to operate within OSHA 29CFR1926.1408, Table
A clearances when the power lines are energized.
Reference Only
Содержание Grove TMS800E13
Страница 5: ...Operator Manual Grove TMS800E13 R e f e r e n c e O n l y ...
Страница 6: ...R e f e r e n c e O n l y ...
Страница 148: ...SET UP AND INSTALLATION TMS800E13 OPERATOR MANUAL 38 Published 02 06 2014 Control 495 00 R e f e r e n c e O n l y ...
Страница 162: ...LUBRICATION TMS800E13 OPERATOR MANUAL 14 Published 02 06 2014 Control 495 00 THIS PAGE BLANK R e f e r e n c e O n l y ...
Страница 166: ...OPERATOR MANUAL TMS800E13 APL 2 R e f e r e n c e O n l y ...
Страница 167: ...R e f e r e n c e O n l y ...
Страница 168: ...R e f e r e n c e O n l y ...