10.1 m (33 ft) Jib
1.
Lower boom and secure tag line (1, Figure 4-41) to tip of
jib. Figure 4-41 shows the 7 m (23 ft) and 10.1 m (33 ft)
extension together.
2.
Disconnect RCL Cable.
a.
Remove connector (1, Figure 4-42) from junction
box on boom nose.
b.
Install dummy plug (1, Figure 4-43) on junction box.
c.
Route cable through jib and stow connector (1,
Figure 4-44).
3.
Remove two pins attaching the jib to the left side of
boom nose (2, Figure 4-45). Stow the pins in the jib pin
holders (1) and install the retainer clips.
4.
Completely retract boom.
5.
Extend boom approximately 60.9 cm (2 feet).
6.
Raise boom above horizontal.
NOTE:
Step 7 is stowing with the 7 m (23 ft) section and
10.1 m (33 ft) section together. If the 7 m (23 ft)
section remained on the boom, proceed to step 9.
7.
Use the tag line to maintain control of the jib, and swing
the extension into the stowed position Figure 4-46.
6642-30
FIGURE 4-41
1
6642-21
FIGURE 4-42
1
6642-20
FIGURE 4-43
1
6642-19
FIGURE 4-44
1
6642-31
FIGURE 4-45
1
2
Reference Only
Содержание Grove TMS800E13
Страница 5: ...Operator Manual Grove TMS800E13 R e f e r e n c e O n l y ...
Страница 6: ...R e f e r e n c e O n l y ...
Страница 148: ...SET UP AND INSTALLATION TMS800E13 OPERATOR MANUAL 38 Published 02 06 2014 Control 495 00 R e f e r e n c e O n l y ...
Страница 162: ...LUBRICATION TMS800E13 OPERATOR MANUAL 14 Published 02 06 2014 Control 495 00 THIS PAGE BLANK R e f e r e n c e O n l y ...
Страница 166: ...OPERATOR MANUAL TMS800E13 APL 2 R e f e r e n c e O n l y ...
Страница 167: ...R e f e r e n c e O n l y ...
Страница 168: ...R e f e r e n c e O n l y ...