NOTICE 

IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS MANITOWOC FOOD SERVICE 
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER  
OR ANY OF ITS AUTHORIZED SERVICERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL 
CONFIGURATION, THIS WARRANTY WILL BE VOID.  FURTHER, FRYMASTER AND ITS AFFILIATES WILL NOT BE 
LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR 
INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART 
RECEIVED FROM AN UNAUTHORIZED SERVICER. 

 

 

NOTICE 

This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster 
Factory Authorized Servicer (FAS) or other qualified professional should perform installation, maintenance, and 
repairs.  Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty.  See 
Chapter 1 of this manual for definitions of qualified personnel. 

 

 

NOTICE 

This equipment must be installed in accordance with the appropriate national and local codes of the country and/or 
region in which the appliance is installed.  See NATIONAL CODE REQUIREMENTS in Chapter 2 of this manual for 
specifics.  

 

 NOTICE 

When installed, this appliance must be electrically grounded in accordance with local codes, or in the absence of 
local codes, with the National Electrical Code, ANSI/NFPA 70, the Canadian Electrical Code, CSA C22.2, or the 
appropriate national code of the country in which installed.

 

 

 

NOTICE TO U.S. CUSTOMERS 

This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and Code 
Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug 
Administration. 

 

 

NOTICE 

This appliance is intended to be used for commercial applications, for example in kitchens of restaurants, canteens, 
hospitals and in commercial enterprises such as bakeries, butcheries, etc., but not for continuous mass production 
of food. 

 

 WARNING 

This equipment is intended for indoor use only.  Do not install or operate this equipment in outdoor areas. 

 

 

NOTICE 

The appliance must be installed and used in such a way that any water cannot contact the fat or oil.   

 

 

NOTICE 

Drawings and photos used in this manual are intended to illustrate operational, cleaning and technical procedures 
and may not conform to onsite management operational procedures. 

 

NOTICE TO OWNERS OF UNITS EQUIPPED WITH CONTROLLERS 

U.S. 

This device complies with Part 15 of the FCC rules.  Operation is subject to the following two conditions:  1) This 
device may not cause harmful interference, and 2) This device must accept any interference received, including 
interference that may cause undesired operation.  While this device is a verified Class A device, it has been shown to 
meet the Class B limits. 

CANADA 

This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 
standard of the Canadian Department of Communications.

  

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans 
la norme NMB-003 edictee par le Ministre des Communcations du Canada. 

 

 WARNING 

Do not use water jets to clean this equipment. 

Содержание 1814E

Страница 1: ...rmation and models are released Visit our website for the latest manual Part Number FRY_IOM_8197317 08 2016 8197317 FOR YOUR SAFETY Do Not Store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Original Instructions CAUTION READ THE INSTRUCTIONS BEFORE USING THE FRYER ...

Страница 2: ...TO U S CUSTOMERS This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the U S Food and Drug Administration NOTICE This appliance is intended to be used for commercial applications for example in kitchens of restaurants canteens hospitals and in commercial enter...

Страница 3: ...ot a step Do not stand on the fryer Serious injury can result from slips or contact with the hot oil DANGER Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance DANGER Do not spray aerosols in the vicinity of this appliance while it is in operation DANGER Keep all items out of drains Closing actuators may cause damage or injury DANGER The...

Страница 4: ... or cooking oil before energizing the elements Failure to do so will result in irreparable damage to the elements and may cause a fire NOTICE If this equipment is wired directly into the electrical power supply a means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring NOTICE This equipment must be positioned so that...

Страница 5: ...nstalling the Oil Saddle Reservoir 2 5 CHAPTER 3 Operating Instructions 3 1 Equipment Setup and Start Up Procedures 3 2 3 2 Operation 3 3 3 3 Oil Attendant Automatic Topoff 3 3 3 3 1 Adding Oil to the Fryer 3 3 3 3 1 1 Install the JIB Jug in Box Oil Reservoir 3 3 3 3 1 2 Adding Oil to the Oil Saddle Reservoir 3 4 3 3 2 Routine Oil Changes 3 4 3 3 2 1 Routine Oil Changes JIB Jug in Box 3 4 3 3 2 2 ...

Страница 6: ...ler Setpoint Accuracy 5 4 5 5 Quarterly Checks and Service 5 4 5 5 1 Replace O rings 5 4 5 6 Annual Periodic System Inspection 5 4 5 6 1 Fryer 5 4 5 6 2 1814E with FilterQuick Filtration System 5 5 CHAPTER 6 Operator Troubleshooting 6 1 Introduction 6 1 6 2 Troubleshooting 6 2 6 2 1 Controller and Heating Problems 6 2 6 2 2 Error Message and Display Problems 6 2 6 2 3 Filtration Problems 6 4 6 2 4...

Страница 7: ...Information Before attempting to operate your unit read the instructions in this manual thoroughly Throughout this manual you will find notations enclosed in double bordered boxes similar to the one below DANGER Hot oil causes severe burns Never attempt to move a fryer containing hot oil or to transfer hot oil from one container to another CAUTION boxes contain information about actions or conditi...

Страница 8: ...ared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 1 4 European Community CE Specific Information The European Community CE has established certain specific standards regarding equipment of this type Whenever a difference exist...

Страница 9: ...S s is located on the Frymaster website at www frymaster com Failure to use qualified service personnel will void the Frymaster warranty on your equipment 1 7 Shipping Damage Claim Procedure What to do if your equipment arrives damaged Please note that this equipment was carefully inspected and packed by skilled personnel before leaving the factory The freight company assumes full responsibility f...

Страница 10: ...y be placed directly with your local FAS or distributor A list of Frymaster Factory Authorized Servicers FAS s is located on the Frymaster website at www frymaster com If you do not have access to this list contact the Frymaster Service Department at 1 800 551 8633 or 1 318 865 1711 or by email at service frymaster com The following information will be needed in order to assist you efficiently Mod...

Страница 11: ...g your local Frymaster Authorized Servicer NOTICE All fryers shipped without factory supplied cords and plug assemblies must be hardwired using flexible conduit to the terminal block located on the rear of the fryer These fryers should be wired to NEC specifications Hardwired units must include installation of restraint devices DANGER Adequate means must be provided to limit the movement of this a...

Страница 12: ...ll automatically shut down If this occurs turn the power switch OFF Do not attempt to start the fryer s until power is restored 2 1 1 Clearance and Ventilation This appliance must be kept free and clear of combustible material except that it may be installed on combustible floors A clearance of 6 inches 15cm must be provided at both sides and back adjacent to combustible construction A minimum of ...

Страница 13: ... 4 11 26 1814E 17kW 240 415 4 6 4 11 24 1814E 17kW 230 400 4 6 4 11 25 1814E 22kW 208 3 4 5 19 61 1814E 22kW 240 3 4 5 19 53 1814E 22kW 480 3 6 4 11 27 1814E 22kW 220 380 4 6 4 11 34 1814E 22kW 240 415 4 6 4 11 31 1814E 22kW 230 400 4 6 4 11 32 Single Phase Requirements MODEL VOLTAGE WIRE SERVICE MINIMUM WIRE SIZE AWG mm AMPS per leg 1814E 14kW 208 2 3 5 83 68 1814E 14kW 240 2 4 5 19 59 1814E 14kW...

Страница 14: ...s appliance without depending on or transmitting stress to the electrical conduit A restraint kit is provided with the fryer If the restraint kit is missing contact your local KES DANGER Hot oil can cause severe burns Avoid contact Under all circumstances oil must be removed from the fryer before attempting to move it to avoid oil spills falls and severe burns This fryer may tip and cause personal...

Страница 15: ...quick disconnect on the bottom of the reservoir Lift up the orange quick disconnect and insert the male adaptor of the hose Once the male end is fully inserted release the quick disconnect to attach Once attached pull gently on the hose to ensure it is connected see Figure 4 Using the enclosed strap attach to the saddle hose as shown Attach to the oil saddle handle to keep the hose off of the floo...

Страница 16: ...FilterQuick Shown Filter Pan Power Switch Drain Valve Switch with LED Lift Rod JIB Reset Switch Basket Holder Manual Holder Oil Saddle Reservoir Pre Screen Filter Pre Screen Filter Wrench Pan Position Display Bulk Dispose Handle TYPICAL CONFIGURATION 11814E with FILTERQUICK ELECTRIC SHOWN NOTE The appearance of your fryer may differ slightly from that shown depending upon configuration and date of...

Страница 17: ...he power cord s is are plugged and locked if applicable into the appropriate receptacle s Verify that the face of the plug is flush with the outlet plate with no portion of the prongs visible 3 Ensure that the power is switched on with the master switch located behind the fryer door cabinet on the front panel of the component box next to the fuse 4 Ensure that the controller is switched ON by pres...

Страница 18: ... will require manual filling upon startup and after disposal Special Cap Has plumbing attached to draw oil from the reservoir to the fryer vats Jug In Box JIB The JIB is the reservoir for the oil JIB Jug In Box Low Reset Switch Resets the ATO system after oil change Figure 1 3 3 1 Adding Oil to the Fryer 3 3 1 1 Install the JIB Jug In Box Oil Reservoir JIB units only Remove the original lid from t...

Страница 19: ...e prompts Once the JIB is replaced or the saddle filled press and hold the JIB button for 5 five seconds to reset top off system Some procedures may differ from photos shown Follow manufacturer s instructions for changing the JIB If using a saddle oil reservoir see section 3 3 2 2 3 3 2 1 Routine Oil Changes JIB only 1 Open the cabinet and slide the JIB from the cabinet see Figure 4 Figure 4 2 Rem...

Страница 20: ... 5 seconds to reset the top off system see Figure 8 on the previous page The system is now ready for operation As the fryer heats to preprogrammed temperatures the system will energize and then slowly add oil to the frypot as needed until the oil reaches an optimal level 3 3 3 Bulk Oil Systems Instructions for installing and using bulk oil systems are found in Appendix A located at the rear of thi...

Страница 21: ...ilter pad or paper MUST be replaced daily or when the sediment level exceeds the height of the hold down ring 4 2 Preparing the 1814E with FilterQuick with Fingertip Filtration System for Use with Filter Paper or Filter Pad The 1814E with FilterQuick with fingertip filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in op...

Страница 22: ... Push the filter pan back into the fryer positioning it under the fryer Ensure A is displayed on the MIB board The filtration system is now ready for use DANGER Do not drain more than one frypot at a time into the built in filtration unit to avoid overflow and spillage of hot oil that may cause severe burns slipping and falling DANGER The crumb tray in fryers equipped with a filter system must be ...

Страница 23: ...f the vat is full press the YES button to continue The controller returns to idle cook mode or OFF If the pot is not filled completely continue to next step 2 Press NO if pot is not filled completely The controller displays FILLING while the pump runs again When the pump stops the controller displays IS VAT FULL alternating with yes no again If the vat is full go to step 1 If the vat is not comple...

Страница 24: ... FIXED alternating with YES NO 10 Press NO to continue cooking Call your FAS to repair and reset the fryer The error will be re displayed every 15 minutes until the issue is repaired Semi automatic filtration and auto top off is disabled until the fryer is reset 4 5 Filter Busy When FILTER BUSY is displayed on the controller the system is waiting on another vat to be filtered or waiting on another...

Страница 25: ...using a bulk oil system follow the disposal and refilling instructions for bulk oil in the FilterQuick Controller Manual 8197206 DANGER When draining oil into an appropriate METAL container make sure the container will hold at least EIGHT gallons 30 liters or more otherwise hot liquid could overflow and cause injury DANGER Allow oil to cool to 100 F 38 C before draining into an appropriate METAL c...

Страница 26: ...rain valve becomes clogged with food particles use the Fryer s Friend poker like tool that was provided with the fryer to clear the blockage DANGER DO NOT hammer on the drain valve with the cleanout rod or other objects Damage to the ball inside will result in leaks and will void the Frymaster warranty 4 After draining the oil clean all food particles and residual oil from the frypot BE CAREFUL th...

Страница 27: ...Particular attention must be paid to the concentration of cleaner and the length of time the cleaner remains on the food contact surfaces 5 2 DAILY CHECKS AND SERVICE 5 2 1 Inspect Fryer and Accessories for Damage Daily Look for loose or frayed wires and cords leaks foreign material in frypot or inside cabinet and any other indications that the fryer and accessories are not ready and safe for oper...

Страница 28: ... water or oil before energizing the elements Failure to do so will result in irreparable damage to the elements and may cause a fire After the fryer has been in use for a period of time a hard film of caramelized oil will form on the inside of the frypot This deposit must be periodically removed to maintain your fryer s efficiency See the Clean and Filter procedure instructions in the FilterQuick ...

Страница 29: ...he FilterQuick controller is reset to proper set temperature for cooking or the fryer will remain at 195 F 91 C temperature DANGER Ensure that the frypot is completely free of water before filling with oil When the oil is heated to cooking temperature water in the frypot will cause splattering 5 3 3 Cleaning the Oil Saddle Reservoir During normal usage of your fryer a deposit of carbonized oil wil...

Страница 30: ...ys or more frequently if the flow of oil slows remove the cap and clean the attached screen 1 Wearing protective gloves use the supplied wrench to remove the cap from the pre filter Figure 1 2 Use a small brush to clear debris from the attached screen Figure 2 3 Clean under a water tap and thoroughly dry 4 Return the cap to the pre filter housing and tighten 5 5 QUARTERLY CHECKS AND SERVICE 5 5 1 ...

Страница 31: ...hat all wiring harnesses and connections are tight and in good condition 5 6 2 1814E with FilterQuick Filtration System Inspect all oil return and drain lines for leaks and verify that all connections are tight Inspect the filter pan for leaks and cleanliness If there is a large accumulation of crumbs in the crumb basket advise the owner operator that the crumb basket should be emptied into a fire...

Страница 32: ...g steps to ensure that it doesn t happen again If a controller malfunctions because of a poor connection check all other connections too If a fuse continues to blow find out why Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system Before calling a service agent or the Frymaster HOTLINE 1 ...

Страница 33: ...wer cord not plugged in A Verify that both the main power cord is fully seated in its receptacle and the circuit breaker is not tripped B Controller has failed B Call your FAS for assistance C One or more other components have failed C Call your FAS for assistance Fryer repeatedly cycles on and off when first started Fryer is in melt cycle This is normal operation This will continue until the frye...

Страница 34: ...s TEMP PROBE FAILURE Problem with the temperature measuring circuitry including the probe or damaged controller wiring harness or connector Shut the fryer down and call your FAS for assistance Controller display shows HEATING FAILURE Failed controller failed interface board open high limit thermostat Call your FAS for assistance Heating indicator is on but fryer is not heating Three phase power co...

Страница 35: ... trip C Blockage in filter pump A Verify that the power cord is fully plugged in and the circuit breaker is not tripped B If the motor is too hot to touch for more than a few seconds the thermal overload switch has probably tripped Allow the motor to cool at least 45 minutes then press the Pump Reset Switch see page 4 5 C Call your FAS for assistance Filter Pump runs but oil return is very slow A ...

Страница 36: ...w C Oil is too cold D JIB out of oil E A fryer may be unplugged or fryer with ATO box may not have power F Service required error exists G Lack of cook A Clean crumbs from opening surrounding sensor B Fryer temperature must be at setpoint C Ensure that the oil in the JIB is above 70 F 21 C D Ensure the JIB is not out of oil and supply line is in the JIB Replace JIB and press the button when prompt...

Страница 37: ...lure E15 ERROR MIB BOARD Cooking controller detects MIB connections lost Check software version on each controller If versions are missing check CAN connections between each controller MIB board failure E16 ERROR AIF PROBE AIF RTD reading out of range E17 ERROR ATO PROBE ATO RTD reading out of range E20 INVALID CODE LOCATION SD card removed during update E21 FILTER PAPER PROCEDURE ERROR Change Fil...

Страница 38: ...ly be performed with old oil Shut the fryer off and call for service immediately if the temperature reaches 460 F 238 C without the high limit tripping and the controller displays HIGH LIMIT FAILURE alternating with DISCONNECT POWER with an alert tone during testing The test is cancelled at any time by turning the fryer off When the fryer is turned back on it returns to the operating mode and disp...

Страница 39: ...the alarm and go to OFF 12 Follow the procedure to dispose of the oil 6 2 8 OQS Oil Quality Sensor Troubleshooting Problem Corrective Action No TPM results displayed Check the following items and perform another OQS filter Ensure the vat is at setpoint temperature Inspect the pre screen filter and ensure it is screwed in tightly Inspect the O rings on the filter pan and ensure they are both presen...

Страница 40: ... and insert the standard fitting into the jug with the metal cap resting on the lip of the jug The oil is pumped in and out of the jug or saddle reservoirs on singles through the same fitting see Figure 4 Figure 4 The momentary switch used to reset the ATO system is also used to fill the jug or saddle in a fresh bulk oil system After clearing the TOP OFF EMPTY display pressing and holding the mome...

Страница 41: ... fryer will ONLY operate with bulk oil systems that have a three pole float switch If the float switch is the older two pole switch call the bulk oil provider These float switches are polarity specific which may short to ground and damage an MIB board ...

Страница 42: ...itchenCare and you choose the level of service that meets your operational needs from one restaurant to multiple locations StarCare Warranty lifetime service certified OEM parts global parts inventory performance audited ExtraCare CareCode 24 7 Support online mobile product information LifeCare Install equipment orientation planned maintenance KitchenConnect MenuConnect Talk with KitchenCare 1 844...