3.10 No Idle Speed
The starting process failed.
Fuel supply may have been insufficient.
3.11 No RPM Signal
No RPM signal could be measured, although the engine was
supposed to be running.
Possibly the turbine is blocked, so that the engine cannot run
up, although the starter is connected. It also can be that the
wiring of the RPM sensor or that the RPM sensor system is
defective or that the signal is influenced by electromagnetic
interference.
3.12 No Configuration
The Engine Control Unit could not load a valid configuration for
the engine.
It must be ensured, that a valid configuration has been stored
on the SD-card, that the SD-card can be accessed and that the
configuration matches the serial number of the engine.
WARNING:
The check, whether the SD-card is inserted
correctly and whether there is a valid
configuration on the SD-card, may only be
performed by M&D or a by M&D authorized
maintenance organisation.
3.13 No SD-Card
The Engine Control Unit could not access the SD-card. This can
occur, if no SD-card was inserted, the initialization of the SD-
card failed or read/write access to the file system was not