28
MP48-R | 1.00.00
www.mc-techgroup.com
Warning
Aggressive media
Aggressive media lead to burns during decommissioning.
Flush the pump under atmospheric pressure conditions with inert
gas. If there is no danger of explosion, flushing can also be carried
out with air.
Aggressive media residues possible.
Wear protective goggles and appropriate protective clothing when
dismantling, repairing, or cleaning the pump.
16 MAINTENANCE
Health hazard due to dangerous substances in the pump
Depending on the substance transferred, caustic burns or poisoning are pos-
sible.
Wear protective clothing if necessary, e.g., protective gloves.
Clean pump with suitable measures
Warning
Risk of injury due to failure to use original parts.
The function of the pump and its safety are at risk if original parts are not used.
The validity of the CE conformity expires if original parts are not used.
Only use original parts from M&C.
Before carrying out maintenance work, the plant- and process-specific safety measures must be ob-
served.
MAINTENANCE SCHEDULE
Check the pump regularly for external damage or leakage.
Check the pump regularly for noticeable changes in noise and vibration.
Replace diaphragm and valve plates/seals at the latest when the pump performance de-
creases.
Check the gas connections regularly for external damage or leakage.