8 AMBIENT
CONDITIONS
The following ambient conditions must be complied with during operation:
Ambient temperature range during operation: +5 to +60 °C [41 to 140 °F], 0 °C [32 °F] if not
condensing (frost-free).
The pumps must be protected from the effects of water and dust.
During operation, a sufficient supply of cooling air must be ensured.
SAFETY
The
MP48-R
pump is designed with
IP54
protection. The pump is dust-protected and protected against
splash water according to VDE 0710 DIN 40050. The motor is designed in protection class
IP55
and is
dust-protected and protected against water jets according to VDE 0710 DIN 40050.
Warning
Aggressive media
Aggressive media lead to burns during decommissioning.
Flush the pump under atmospheric pressure conditions with inert
gas. If there is no danger of explosion, flushing can also be carried
out with air.
Aggressive media residues possible.
Wear protective goggles and appropriate protective clothing when
dismantling, repairing, or cleaning the pump.
Note that the pumps are only to be used for their intended purpose.
Note
The components to be connected to the pumps must be designed for
the pneumatic data of the pumps.
Observe the corresponding safety regulations when connecting the
pumps to the electrical network.
The corresponding safety regulations must be observed for the media
to be pumped.