background image

Ref.: WB-VL-65 DSP LX Premium - OM Ver.1.6 (B2927) 

24

 

Rim distance measurement

 (Applicable only for Dynamic balancing)

 

After mounting wheel with appropriate accessories as explained in Chapter 
7.3, enter Rim distance, by following any one of the methods given below:

  

 

Move the Distance measuring rod outwards till it 
touches the Inner rim (Refer Fig.21). Keep the 
Distance measuring rod in the same position for 
atleast 3 seconds.  The Rim distance will be updated 
on the window followed by an Audio indication.

 

 

Use the Navigation keys to set the Rim distance 
value manually. 

 

Rotate the wheel to set the Rim distance value 
manually and hold the wheel when the desired 
distance value is displayed. 

 

 

 

  

 

 

 

 

 

 

 

  Fig. 21 

if 

Auto Dia 

measurement is enabled, both the Distance & Diameter windows 

will be highlighted. Now move Distance/Dia measuring rod outwards till it 
touches the Inner rim & keep it in the same position for alteast 3 seconds.  
Rim Distance & Diameter will be updated on the window followed by an Audio 
indication. Then move Distance measuring rod to its Home position. 
If 

Auto Dia / Auto Width

 measurement is enabled, the system will detect the 

Rim type automatically. After the Inner distance measurement, if the Distance 
rod is further moved to measure the Inner most distance, then the Rim type 
(either ALU2 or ALU3) will be detected based on the location of measurement. 
If the Distance rod is moved back to Home position and then Width rod moved 
to measure the Rim Width, then the Rim type (ALU4, ALU-5 & Steel) will be 
detected automatically depending on location of measurement. 

 

Automatic Rim type detection is applicable only in Dynamic mode 

 

 

The Distance / Dia measuring rod and the Width rod to be touched at 
the approximate middle area for the Sticker weight adding location 
during measurement. Whereas, it has to be touched at curved edge of 
rim for the Clip on weight adding locations. If the location is wrongly 
measured, it will lead to wrong selection of Rim type by the Automatic 
system 

 

 

For Steel & ALU1 type, the Rim type will be indicated as “STEEL” only 
as the condition is same. If the User wants to change the Rim type to 
ALU1, it can be changed manually using the Navigation keys 

Once a Rim parameter is acquired, the system will go to next parameter 

window automatically after few seconds. User can also press 

 /

 key to 

go to previous / next window respectively.

 

 

Ensure the Distance/Dia measuring rod contact pin touches the Inner 

rim profile at the exact place where the weight to be added to acquire 

the correct Rim distance & Diameter and also the correct Rim type 

 

 

If the parameter is acquired, the value will be indicated in YELLOW 
color and background will be highlighted 

 

Rim diameter measurement 

Diameter window will be highlighted. Then enter the Rim dia by following any 
one of the methods given below: 

 

Measure the Diameter of the Rim and set the value using Navigation 
keys. 

 

Rotate the wheel to set the Rim dia value manually and hold the wheel 
when the desired distance value is displayed 

if 

Auto Dia

 measurement is enabled, the Rim diameter will be updated 

automatically during Rim distance measuring itself 

Содержание LX WB-VL-65 DSP

Страница 1: ...VIDEOGRAPHIC WHEEL BALANCER WB VL 65 DSP Premium Premium OPERATING MANUAL Ver 1 6...

Страница 2: ...balancer leaving our Factory is in the best operating condition This OPERATING MANUAL has been prepared to help you in getting the best performance out of the equipment Still if you have any doubt ple...

Страница 3: ...3 DISPLAY UNIT 15 6 4 CONTROL PANEL 15 6 5 WHEEL GUARD 15 6 6 STANDARD ACCESSORIES 16 6 7 OPTIONAL ACCESSORIES 17 7 OPERATION 18 7 1 DEFECTS MALFUNCTIONS 18 7 2 PREPARATION OF WHEEL FOR BALANCING 18 7...

Страница 4: ...lar the equipment must be installed and operated in protected environments where there is no risk of dripping or direct sunlight 5 Ensure that any equipment which produces Ultra Violet rays is not ava...

Страница 5: ...ate accessories for mounting various types of wheels 2 2 SAFETY INSTRUCTIONS FOR COMMISSIONING 1 Only authorized service personnel are allowed to install and commission the Wheel balancer 2 DO NOT HOL...

Страница 6: ...o not lift the Wheel guard until the wheel rotation is completely stopped 11 Never overload the Balancer 12 Do not keep heavy objects over the system except limited quantity of Wheel balancing weights...

Страница 7: ...eel from hitting the Distance measuring rod while running ie if the Distance measuring rod is not in home position the wheel run will not be carried out and an Error code Distance rod is not in Home p...

Страница 8: ...ectrical safety Part No B2945 B2946 Safety instruction for operation II Part No H3635 Indicator for direction of rotation of wheel Part No H3636 Mechanical brake attention Part No H3632 Foundation War...

Страница 9: ...balancing sequence 16 Compact simplified Membrane keypad 17 Safety Warning messages 18 On screen help notes messages 19 Fully automatic start measurement and braking 20 Static Single plane Dynamic Tw...

Страница 10: ...z 0 35HP 1 60 50Hz 2 Motor speed 230V 50 60Hz operation 110V 60 50Hz operation 960rpm 1200rpm 3 Power supply 230V 50 60Hz operation 110V 60 50Hz operation 230VAC 10 1 50 60Hz N PE 110VAC 10 1 60 50Hz...

Страница 11: ...ly to the equipment must be connected through a CE certified MCB with ratings as given below For 230V 50 60Hz operation Two pole Type C 6A MCB For 110V 60 50Hz operation Two pole Type C 10A MCB Proper...

Страница 12: ...ackage contents Qty 1 Main cabinet corrugated box 1 Main cabinet assembly 1 No 2 Monitor 1 No 3 Monitor column 1 No 4 Wheel guard with pipe DMR 1 No 5 Width caliper 1 No 6 Width measuring rod 1 No 7 A...

Страница 13: ...M16 Spring washer Flat type between the Cabinet and Floor 5 Fix the Cabinet with foundation bolts using Nut Washer that comes along with Anchor bolt 6 Check of any tilt Use required quantities thickne...

Страница 14: ...5 Bring the Width assembly cable through the bracket and connect Male end of Wire from Width measuring rod to female end provided below the Bracket at the rear side of cabinet 6 Fix the Safety cover w...

Страница 15: ...be carried out Balancing is the process of finding out the Mass which causes unbalance and the location phase of the mass and adding equal weight in the directly opposite location 180 away Fig 7 5 2 S...

Страница 16: ...rent based on the configuration of Alloy rim refer Chapter 7 4 1 The Diameter Width of the Rim and the Rim distance are the inputs to the equipment for calculating the unbalance When the distance from...

Страница 17: ...d Control panel Mains power cable is situated at the rear side of Cabinet ON OFF switch is provided at side of cabinet Control fuses are incorporated to protect electronic assemblies against short cir...

Страница 18: ...ns To select the SETTINGS button in WELCOME screen To proceed with next step screen in balancing operations To clear error messages Pressing the key twice within a second will start balancing operatio...

Страница 19: ...Medium taper Min 52 5 Max 70mm Code P9363 Wheel seating dual cone Medium taper Min 66 Max 83 5mm Code P9364 Wheel seating dual cone Medium taper Min 80 Max 97 5mm Code P9365 Wheel seating dual cone M...

Страница 20: ...e 157mm Code A2826 Wheel seating cone with spacer Tata 407 For Wheel bore 162mm Code A2827 Wheel seating cone Taper 2 23 Code P9226 Wheel seating cone Taper 2 58 Code P9227 Wheel seating cone Taper 2...

Страница 21: ...after clearing the indicated error 7 1 DEFECTS MALFUNCTIONS In case of defects or malfunctions such as abnormal noise improper display Keypad not responding etc turn OFF the mains and contact qualifie...

Страница 22: ...th bigger dia end butting against the MCD Slide the Wheel seating cone on to the MCD shaft with its larger diameter butting against the MCD face as shown in Fig 13 Lift the wheel on to the shaft and c...

Страница 23: ...im Lift the wheel on to the shaft and slide it to butt against the Spacer Position the cone onto the centre hole diameter of the rim and insert it to the shaft along with the wheel Insert the QCLN wit...

Страница 24: ...eels with 5 mounting holes Fig 16 Measure the pitch distance of the mounting hole in the wheel using PCD measuring tool provided and tighten the measuring tool in the same position without disturbing...

Страница 25: ...3 Alloy wheels Balancing weights is applied on the Inner plane only Split weight functions cannot be done in Static balancing mode Switch ON the equipment and wait for a minute approx Program will loa...

Страница 26: ...ed If the Job count reaches maximum count of 99999 a message will be prompted the system will reset the count to 00001 automatically 7 4 1 RIM PARAMETERS While setting Rim parameters using Navigation...

Страница 27: ...th then the Rim type ALU4 ALU 5 Steel will be detected automatically depending on location of measurement Automatic Rim type detection is applicable only in Dynamic mode The Distance Dia measuring rod...

Страница 28: ...ollowed by an Audio indication Rim selection The selected Rim type will be displayed in the Status bar of RIM PARAMETERS screen Wheel Rim types Steel rims Clip on weights for both Inner and Outer plan...

Страница 29: ...f the Laser line If Weight Calibration data is not available Redo weight calibration or Restore Factory calibration message is displayed press key to clear message Calibration to be done before procee...

Страница 30: ...tion only The Torch can be switched On Off as desired by using button In Laser mode unbalance position will be indicated for Inner Inner most position Repeat the above steps for Outer plane also Spin...

Страница 31: ...s key Following screen will be displayed Fig 26 No of spokes that can be accommodated is min of 3 spokes max of 12 spokes Select the appropriate Nos of Spokes with respect to the number of spokes avai...

Страница 32: ...the wheel as explained in Chapter 7 4 2 or press key to exit from Split weights program to go to WHEEL RUN screen 7 5 2 OPTIMIZATION FUNCTION Optimization is normally done to reduce the Static unbala...

Страница 33: ...ompleted close the Wheel guard or press key twice Optimization completed message will be displayed the system will go to POSITION TRACKING screen and run the wheel automatically To exit from Optimizat...

Страница 34: ...or Disabling Buzzer indication throughout balancing program Settings Enabling or Disabling Auto run function in Wheel balancing operation Enabling or Disabling Automatic Distance measurement Enabling...

Страница 35: ...nsure the foundation is proper 2 Ensure the Cabinet is free from shake 3 Check the Belt tension and RPM The RPM should be 175 20 5 Pre calibration Applicable for Factory Authorized Engineer Following...

Страница 36: ...im dia 16 Unbalance should be 50gm min For Single point use a fairly balanced wheel with Rim dia 12 24 Unbalance should be 30gm min Use keys to move to next parameters Two point calibration Low Point...

Страница 37: ...nd ensure wheel mounted is with minimum unbalance To know the millivolts of Raw calibration after completing Tyre zero press key to go to RAW CALIBRATION run the wheel to view millivolts of SA SB disp...

Страница 38: ...ration if Calibration weight signal is too high Press Key to proceed or any other key to exit error message appears check whether the correct calibration weight is added on the appropriate plane or we...

Страница 39: ...played voltage is not within specification loosen the lever fixing Allen screw and Grub screw to move the DMR slightly and then rotate the Lever fixing rod till required voltage is set Touch the Beari...

Страница 40: ...ie Stopper Position and ensure the displayed Width voltage Outer Dia voltage is 1 00V 0 1V 2 50V 0 1V respectively If the displayed Outer dia voltage is not within specification move the Width assembl...

Страница 41: ...Touch the Width rod at the top edge of MCD and hold it for few seconds till Audio indication and then move the Width rod to Home position The system will go to WIDTH CALIBRATION screen Select WHEEL C...

Страница 42: ...in RIM PARAMETERS screen are as per the Wheel Width specifications within tolerance limit of 0 3 9 4 WHEEL TRACKING TEST This feature should be used only by authorised Service personnel Hence User sh...

Страница 43: ...module 9 14 RESTORE FACTORY CALIBRATION This feature should be used only by authorised Service personnel Hence User should not enter into this module 9 15 WEIGHT CUTOFF This feature should be used on...

Страница 44: ...nting and removing which may affect the accuracy of the equipment Apply a thin layer of machine oil on the MCD flange and shaft for rust prevention Wipe off the excessive oil and keep them clean DO NO...

Страница 45: ...nnection 5 Spark in the Mains cord socket Loose connection in the AC supply socket Connect the power mains with proper plug socket combination 6 Wheel is not balanced and repeatedly asking weights Imp...

Страница 46: ...pecified range Use fairly balanced wheel and do the calibration 14 Width rod is not in Home position The Width rod may not be at home position Ensure that the Width rod is in home position Check for t...

Страница 47: ......

Страница 48: ...acturer All information illustrations and specifications contained in this Manual are based on the latest information available at the time of publication Manufacturer reserves the right to make chang...

Отзывы: