Commissioning and operation
29
System fault:
There are 2 different failure states, which are indicated by the failure LED flashing or
being continuously lit:
−
A flashing system fault LED indicates a communication fault, i.e. at least one of the
data buses is interrupted or disturbed. In this case, the plug connections on the MMDS
D08-L and the MMDS-SD serial distribution box must be checked for correct seating.
−
A continuously lit system failure LED indicates an internal fault. The unit is faulty if this
status persists after it is switched off and on again.
Operation:
At the front are three buttons with which various functions such as Alarm-Quit are poss-
ible. The buttons have the following functions:
Standard function:
Acoustic quit or switch-off of the internal horn.
All other monitoring devices in the system are quitted too.
Test function:
Holding the key for at least 5 seconds activates the built-in buzzer.
Standard function:
Visual quit, i.e. all flashing alarms stop flashing but remain lit
provided that an acoustic quit was previously activated. All other monitoring devi-
ces in the system are quitted too.
Test function:
Lamp test, i.e. all LEDs are activated for as long as the button is
pressed.
Standard function:
If the reason for the alarm has been eliminated and a quit has
been activated the reducing or stop alarm can be reset in the central unit using
this button.
Содержание D 0836 LE 401
Страница 1: ......
Страница 2: ......
Страница 3: ...3 Operating Instructions MAN Marine Diesel Engines ...
Страница 4: ...4 ...
Страница 9: ...Declaracion 9 ...
Страница 17: ...Notes 17 ...
Страница 18: ...Commissioning and operation 18 Engine views D 0836 LE 401 11 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 ...
Страница 69: ...Notes 69 ...
Страница 75: ......
Страница 76: ......