Front Loading Utensil Washer Disinfector (WDF)
Operation, Maintenance and Installation Manual
Issue 1
Page
16
20/01/2022
Fault 20
Contactor Fail
(No feedback from contactor when ON)
Cause
Failed contactor
Wiring fault
Fault 21
Heating Fail
(No temperature rise seen during heating stage)
Cause
Over temperature protection device tripped
Blown element
Fault 22
Hot Wash Over Temp
(Control temperature set point tolerance exceeded)
Cause
Element relay fault
Temperature probe fault
Fault 23
Hot Rinse Over Temp
(Control temperature set point tolerance exceeded)
Cause
Element relay fault
Temperature probe fault
Fault 24
Disinfection Over Temp
(Control temperature set point tolerance exceeded)
Cause
Element relay fault
Temperature probe fault
Fault 25
Door Open
(Door detected open during cycle)
Cause
Door lock fault
Door position sensor fault
Door position sensor out of adjustment
Fault 26
Door Lock Fault
(Door unlock detected during cycle)
Cause
Faulty Door Lock Position Sensor
Door lock fault
Fault 27
Machine Contactor Fault
(Contactor state does not change when switched)
Cause
Failed Contactor
Controller Output Failure
Fault 28
Wash Pump High
(High current draw detected)
Cause
Pump impeller jammed
Start capacitor failure
Wash pump mechanical failure
Fault 29
Wash Pump Low
(Low or No current draw detected)
Cause
Start capacitor failure
Motor Failure
Wash pump mechanical failure
Fault 30
Unknown Load
(Load Detected outside or cycle)
Cause
Pump impeller jammed
Start capacitor failure
Wash pump mechanical failure
Fault 31
Cycle Time Exceeded
(Maximum allowable cycle time exceeded)
Cause
Low water pressure
Element leg failure
Fault 32
Disinfection Temp Fault
(Disinfection Temp not held)
Cause
Element Fault
Temp Sensor Fault
Phase dropped
Fault 33
Disinfection Time Fault
(Disinfection holding time not achieved)
Cause
Controller Failure
Содержание WDF-3020
Страница 34: ......
Страница 35: ...Manufactured by Malmet Australia Pty Ltd ABN 95 001 717 791 www malmet com au Part No 92 2226...