21
4 Unpacking and Checking Contents
• Gauge this tooth with the dowel rod. If the tooth is in the same position, relative to the miter gauge slot, the
table is parallel with the blade. In short, the miter gauge slots must be parallel with the blade. This means
that when measuring distance between blade and miter gauge slot at the front and rear of the blade, the
distances will be equal.
NOTE: Be sure to measure the distance or make the test on the same tooth of the saw blade in both front and
rear positions.
RAIL ASSEMBLY
Refer to following fi gure.
• Insert four M8 x 25 hex head bolts into the T-slot of the right front guide rail.
• Attach right front rail to the table and right table extension using fl at washers, and hex nuts.
NOTE: Hand tighten all hardware during rail assembly. Do not completely tighten hardware until all rails are
mounted.
• Attach left front rail in the same manner.
NOTE: You may have to shift right rail as far right as it will go to attach left rail.
• Position rails so that rails are butted together and blade mark on the right rail is aligned with the blade. You
may need a mallet to lightly tap rails together. Make sure rails are completely butted together at the joint.
• Check and make certain that front rail are parallel to the table surface. Then tighten the screws completely.
• Attach short and long rear rails to the table and table extension using M8X25 socket head bolts, fl at washers,
and hex nuts
Содержание SC.1100.X
Страница 11: ...11 2 Safety Regulations ...
Страница 40: ...40 8 Exploded View 8 Exploded View ...
Страница 43: ...43 8 Exploded View ...
Страница 45: ...45 8 Exploded View ...
Страница 48: ...48 8 Exploded View ...
Страница 50: ...50 9 Wiring Diagram WIRING DIAGRAM 3 Wire 220V 1Phase 9 Wiring Diagram ...