3.4.6. Manual work of the stirrer. 

In addition to the automatic work of the stirrer, the controller allows you to manually 
switch on the stirrer at any time (when the  stirrer is  not working). Depending on the 
settings made in the CP parameter, you can set two variants of manual work: 

 

CP=0  –  continuous  stirrer  operation  from  the  moment  of  manual  activation  until  
the manual switch-off,

 

 

CP>0 – work for a specified period of time; the value of the CP parameter (>0) means 
the  working  time  of  the  stirrer  activated  manually;  the  stirrer  operation  in  this 
variant can also be interrupted at any time by pressing the button 

.

 

 
3.4.7.  Saving  the  maximum  and  minimum  temperature  values  during  the  cooling 
process. 

The controller has a function of saving in its internal memory maximum and minimum 
temperature  values  that  occur  throughout  the  controller's  entire  cycle.  This  function 
makes  it  possible  to  check  whether  the  contents  of  the  tank  are  stored 
in correct temperature conditions. 
At  the  moment  the  cooling  is  switched  on,  after  the  programmed  delay  has  elapsed 
(parameter  AA  –  see  section  3.4.1.  Table  of  settings  for  the  cooling  segment),  
the minimum and maximum temperature values  are saved in  the controller memory. 
The programmable delay time of enabling this function allows the fresh milk to be pre-
cooled and thus does not take into account the maximum temperature when the cooling 
is started. The factory setting is 2 hours, however, this time should be selected according 
to the actual operating conditions of the controller. 
At any time, you can read the currently available maximum and minimum values. This is 
done by briefly pressing the S button and selecting the parameter H0 (maximum value) 
or parameter L0 (minimum value). 
 

ATTENTION 
In  the  absence  of  entries  of  maximum  and  minimum  temperature  values  in  the 
controller's memory the symbol --- appears on the display. 

 
Clearing the memory of maximum and minimum temperature values is caused: 

 

automatically after turning the cooling off and on again; switching off the cooling 
itself does not erase the memory, it takes place only after switching it on again, 

 

in the event of a power failure. 

 
3.4.8. Saving the maximum temperature value during the washing process. 

The maximum temperature that is present when the controller is not in cooling mode is 
also written to the controller's internal memory. Because the washing process must be 
carried  out  with  the  cooling  off,  the  temperature  then  present  is  also  the  maximum 
temperature in the washing process. However, if the washing process is not carried out 

Содержание MCH-07 v. 2

Страница 1: ...n accidentally to activate the washing process during the cooling process The washing segment is activated only when the cooling is switched off The MCH 07 v 2 controller has a waterproof casing prote...

Страница 2: ...ROLLER In order to install the controller unscrew the six screws and swivel the front of the controller paying attention to the cable connecting the upper PCB board with the bottom board After unfoldi...

Страница 3: ...n to drill the housing and fix the casing through such holes because it causes loss of tightness of the casing MCH 07T version In the event that the relay no 4 in the washing segment is set as the sti...

Страница 4: ...no 5 3 COOLING SEGMENT Activation of the cooling process by the user blocks the possibility of switching on the washing process which results in the total turning off of the washing segment display vi...

Страница 5: ...e stirrer 10A 250V AC 3 2 Controller functions in the cooling mode The cooling segment of the MCH 07 v 2 controller is equipped with the functions described below 1 Function that allows controlling th...

Страница 6: ...s mode and make the required corrections The following figure illustrates the programming procedure 3 4 Cooling segment operation by the installer Entering the settings can be made both when the cooli...

Страница 7: ...aximum working time of the unit2 CC 0 off 0 on the possibility of setting the time from 0 h to 9 h every 1 h 0 minimum standstill time of the unit CF 0 off 0 on the possibility of setting the time fro...

Страница 8: ...l diode is permanently on FC 0 during the time set in this parameter initial cooling takes place according to the settings made in parameter t1 during the initial cooling the cooling signal diode blin...

Страница 9: ...compressor safety functions such as CF minimum standstill time of the unit CA minimum operating time of the unit CC maximum working time of the unit Setting of these parameters can also affecton actua...

Страница 10: ...alues are saved in the controller memory The programmable delay time of enabling this function allows the fresh milk to be pre cooled and thus does not take into account the maximum temperature when t...

Страница 11: ...switch on the controller supply voltage again After performing the above described activities the controller will return to the factory settings therefore any changes made to the settings will be del...

Страница 12: ...re t1 5 0 pre cooling temperature the function is active at the FC 0 setting see section 3 4 1 Table of settings for the cooling segment t2 5 0 recalling from the controller memory the maximum tempera...

Страница 13: ...utton The unit then works in an automatic cycle according to the settings made The operation of the stirrer is indicated by the diode located above the button Pressing the button causes manual operati...

Страница 14: ...CH 07 v 2 controller is activated only when cooling is switched off this activation is indicated by the appearance of the symbol on the display The washing segment may vary depending on the version of...

Страница 15: ...imum number of steps in each program 50 minimum duration of one step 1 s maximum duration of one step 99 min range of the control temperature only MCH 07T v 2 version from 9 0 OC to 99 0 OC resolution...

Страница 16: ...this function UAP parameter see section 4 3 1 Table of settings for the washing segment it is possible to temporarily limit the possibility of returning to the interrupted controller in range from 1...

Страница 17: ...obtaining a signal from a hydrostatic This function is secured by setting the maximum time for pouring water in the event of mechanical suspension of the hydrostatic 4 2 12 Water heating control only...

Страница 18: ...out active maximum time 2 setting the maximum loss of power time after which the controller will return to the interrupted operation UAP 0 off resuming operation is not time limited 1 the possibility...

Страница 19: ...3 2 2 Selecting the function to be edited In section 4 3 1 Table of settings for the washing segment all available functions are given with their description and possible values to be set If you want...

Страница 20: ...elay outputs hydrostatic input status duration of the step When programming or editing an existing program the following buttons perform the following functions changing the value of a setting upwards...

Страница 21: ...it is recommended to create a table as shown in the description of the programs This will facilitate efficient programming 3 In the event of inactivity during programming the controller automatically...

Страница 22: ...for the time programmed for a given step to elapse In order to set the test mode enter the settings and change the UEL parameter to 1 then confirm by pressing the S button The controller test operatio...

Страница 23: ...p step duration CW ZW PP PML ZZ PMY 1 15 00 0 1 0 0 0 1 0 1 max time 2 03 00 0 0 1 0 0 1 0 0 3 00 30 0 0 1 1 0 1 0 0 4 15 00 1 0 0 0 1 1 0 1 max time 5 07 30 0 0 1 0 1 1 0 0 6 03 30 0 0 1 0 0 1 0 0 7...

Страница 24: ...ZW PM PPR ZZ PMY 1 02 30 0 1 0 0 0 1 0 0 2 01 00 0 1 1 1 0 1 0 0 3 01 00 0 0 1 1 0 1 0 0 4 02 30 0 0 0 0 1 1 0 0 5 02 30 1 0 0 0 0 1 0 0 6 01 00 1 0 1 1 0 1 0 0 7 04 30 0 0 1 1 0 1 0 0 8 03 00 0 0 0 0...

Страница 25: ...remains in a state of readiness for operation This is signaled by appearing symbol on the display The washing program is activated by pressing the start button and it is signaled by the symbol From th...

Страница 26: ...d UPP parameter see section 4 3 1 Table of settings for the washing segment the user has the option of manually activating the vacuum pump or the stirrer operation relay no 4 Default settings or made...

Отзывы: