19 / 23
7-2
Wiring in Motor housing L
Sub controller
(for the product with
Auto start wirelesss
Controller
Terminal
Switch
Rib F
Rib E
Connector for the product
Equipped with Auto start
wireless system)
Noise suppressor
Put Noise suppressor to this space.
Put lead wires to the space between Rib E and Rib F.
And the lead wires, connected Noise suppressor, have to
be put on the lead wires connected to Terminal.
Fix lead wires of Switch unit with these
Lead wire holders.
Put Connectors to this place positioning their pieces as follows.
*Connector pieces , put on the Controller side: Connector pieces with Controller’s lead wires
( The product equipped with Auto start wireless system, has two connector pieces..
* Connector piece, put on the Switch side: Connector piece with lead wires of Switch unit
Connector piece with lead wires of Sub controller
Switch unit
Do not put any lead wires on this Rib.
Dial section
Lead wires of Controller, connected to Dial section,
have to be put between Rib G and Rib H.
Rib H
Rib G
*After setting dial section and
Auto-start wireless
system