7
ENGLISH
Prefilter or high performance filter
and HEPA filter
1
2
3
4
Fig.7
►
1.
Capsule
2.
Prefilter
3.
High performance filter
4.
HEPA filter
NOTICE:
Do not underlay the high performance
filter with an optional filter (non-woven cloth).
The
filters could not be removed from the cleaner.
NOTE:
Do not install an optional filter (non-woven
cloth) between the HEPA filter and prefilter. The suc
-
tion power may be reduced.
NOTE:
Always use the high performance filter that is
framed with an originally-designed stay when overlay-
ing it on the HEPA filter.
2
1
Fig.8
►
1.
High performance filter
2.
Stay (designed for high
performance filter)
Disposing of dust
CAUTION:
Empty the cleaner before it
becomes too full, or the suction force weakens.
CAUTION:
Be sure to empty the inside of the
cleaner itself of dust.
Failure to do so may cause the
filter to be clogged or the motor to be damaged.
In order to drop dust sticking on the filter in the capsule,
tap the capsule 4 or 5 times with your hand.
1
Fig.9
►
1.
Capsule
Point suction inlet downwards, turn capsule in direction
of arrow in diagram, and disconnect capsule slowly and
straight.
1
2
Fig.10
►
1.
Capsule
2.
Suction inlet
NOTE:
Dust may spill out when capsule is opened, so
be sure to set a garbage bag beneath capsule.