background image

2

Majestic Fireplaces

®

 SR/SC Series

Safety Information

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.

IMPORTANT: Read all instructions and warnings carefully before starting installation.  Failure to
follow these instructions may result in a possible fire hazard and will void the warranty.

Description

The SR/SC Series fireplaces are solid fuel, woodburn-
ing premium fireplaces. The SR36/42 are radiant
clean-face models and the SC36/42 are circulating
models with removable grilles (louvers). Both models
are fully insulated fireplaces.

Precautions

Vermont Castings, Majestic Products fireplaces and
component parts have been highly tested and will
operate safely when installed in accordance with
instructions provided in this manual. Carefully read
and understand all instructions before beginning
installation.

If you notice any damage to fireplace or component
parts, immediately report damage to your Vermont
Castings, Majestic Products dealer.

Only use Vermont Castings, Majestic Products compo-
nents or the warranty will be voided and a fire hazard
may be created.

Vermont Castings, Majestic Products warranty will be
voided by and Vermont Castings, Majestic Products
disclaims any responsibility for the following actions:

• Installation of any damaged fireplace or

chimney component;

• Modification of fireplace, chimney assembly

or any component parts thereof; (except for
chase flashings as detailed in Vermont Castings,
Majestic Products Chimney Top installation
instructions).

• Installation other than as instructed by

Vermont Castings, Majestic Products; or

• Installation and/or use of any component

part not manufactured or approved by
Vermont Castings, Majestic Products in
combination or assembly with a Vermont
Castings, Majestic Products fireplace sys-
tem, notwithstanding any independent
testing laboratory or other third party ap-
proval of such component parts or acces-
sory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in
compliance before installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any
manner.

Do not install combustible materials on any of the
black fireplace surround.

Burn only solid wood fuel or gas logs.

Do not install a solid fuel burning insert or other
products not specified for use with this fireplace.

These fireplaces are not approved for installation
in mobile homes.

Drafts

The fireplace should not be located in areas that
create drafts (ie: frequently opened doors and central
heating air inlets/outlets) that hamper the normal flow
of air into the fire.

Gas Logs

If you plan to install a gas log, the gas line should be
installed before framing the fireplace. The gas line
must be installed by a certified gas line installer.

Safety Information . . . . . . . . . . . . . . . . . .  2

Specifications and Framing . . . . . . . . . . .  3

Parts Identification . . . . . . . . . . . . . . . . . .  5

Chimney Requirements . . . . . . . . . . . . . .  6

Planning Information . . . . . . . . . . . . . . . .  7

Installation . . . . . . . . . . . . . . . . . . . . . . . .  8

Replacement Parts . . . . . . . . . . . . . . . .  19

Accessories . . . . . . . . . . . . . . . . . . . . . .  20

Table Of Contents

SR36 / SR42
SC36 / SC42

Listed

UL / ULc127

Standard for Factory Built Fireplaces

Содержание SC36

Страница 1: ...678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 1234567890123...

Страница 2: ...ings Majestic Products Chimney Top installation instructions Installation other than as instructed by Vermont Castings Majestic Products or Installation and or use of any component part not manufactur...

Страница 3: ...97mm 7 191mm 7 191mm Outside Air Gas Line Access Gas Line Access Electrical Access Recessed Nailing Flange 11 DIA Rough Opening Width 41 Rough Opening Height Rough Opening Depth 3 4 8 7 6 m m 1041mm 1...

Страница 4: ...epth 50 1270mm 50 1270mm 3 6 9 1 4 m m 7 0 1 7 9 1 m m 8 210mm 22 559mm 22 572mm 26 667mm 40 1035mm 14 372mm 15 397mm 9 241mm 3 76mm 8 203mm 7 191mm Outside Air Gas Line Access Electrical Access 1194m...

Страница 5: ...Fireplace and chase parts identification TERMINATION CAP STORM COLLAR PAN FLASHING DRAFTSTOP FIRESTOP STANDOFF NAILING FLANGE GAS LINE ACCESS both sides ELECTRICAL ACCESS OUTSIDE AIR COVER PLATE DAMPE...

Страница 6: ...exit SR SC36 SR SC42 Maximum 90 90 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbo...

Страница 7: ...of the chimney to the peak of the roof is 10 feet or less the top of the chimney must be at least 2 feet above the peak of the roof but never less than 3 feet in height above the highest point where i...

Страница 8: ...A FIRE PLACE IN AN INSULATED ENCLOSURE BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED Fig 20 Page 14 Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney...

Страница 9: ...Remove knockout in the center of the back of the EB1 and install listed cable clamps Feed electrical wire through listed cable clamp leaving approximately six 6 inches of wire exposed through the EB1...

Страница 10: ...pass through ceiling Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used Measure your offset dimension from straight up chimney center point on ceil...

Страница 11: ...t by attaching the first chimney section to the collar on top of the fireplace Install the pipe as pictured in Figure 16 When you get a good lock you will hear the pipe clearly snap together Once sect...

Страница 12: ...lange on the ceiling side and the angled portion extending up into the hole If the area above the ceiling is an attic position the firestop spacer with the flange on the top of the framed hole and the...

Страница 13: ...point of the flue system Drive a nail up through roof at the center point This will determine center point on outside of the roof Cut and Frame Roof Hole Size of roof hole varies with the type of chi...

Страница 14: ...Fig 20 8 Finish Wall Finish the wall with material of your choice Do not install a combustible mantel shelf less than 12 inches above the grille opening If a combustible material is used below a flat...

Страница 15: ...cified for the SP40 Rt must 1 85 minimum Examples of wall shield insulation 1 Manville CERAFORM 126 K 27 1 2 inches thick 2 Majestic EH2416 K 458 1 inch thick required FP531 See mantel drawing for she...

Страница 16: ...rial Factors are related by the formula K 1 R T given thickness R thermal resistance for a given thickness T K thermal conductivity Noncombustible material with a lower R value may be used provided th...

Страница 17: ...new material per inch K of listed material per inch thickness of listed material x Example for Common Brick T new 5 0 0 458 x 0 50 in 5 46 in new required thickness Fig 24 Hearth extension material f...

Страница 18: ...ace side NOTE When installing an ANSI Z21 11 2 ventless appliance the finishing material used for the mantel must be rated at 250 F or greater BTU input of a gas appliance installed in fireplace shoul...

Страница 19: ...2 3030172 8 Screen Clips 7512135 7512135 9 Hearth Pan Cover Plate SC Only 3031104 3031104 10 Outer Collar Assembly SK8 Chimney 3030143 3030143 11 Nailing Flange 2253161 2253161 12 Top Grille Assembly...

Страница 20: ...h action may void the coverage provided by the owner s insurance Glass Door Standard Bi Fold door set Brushed Brass finish 36GDKBB SR C36 42GDKBB SR C42 Black finish 36GDKBK SR C36 42GDKBK SR C42 Poli...

Страница 21: ...ney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low profile pyramid style...

Страница 22: ...Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Chimney...

Страница 23: ...t at a cost to the consumer of Vermont Castings Majestic Products then current list price FOB Vermont Castings Majestic Products factory or pay to the consumer the then current wholesale price of such...

Страница 24: ...c Fireplaces SR SC Series Vermont Castings Majestic Products 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com Vermont Castings Majestic...