1.  Insulating Fireplace Enclosure

For Cold Climates

If you live in a cold climate, it is not required but
highly recommended that you insulate fire-
place enclosure to eliminate cold air penetration
as much as possible.

Insulate base of fireplace with a non-combus-
tible insulation rated for a minimum of 300
degrees F.  Insulating is very important for
outside wall installations over a concrete slab. If
fireplace is installed on a platform, insulation
should be placed on top of the platform before
fireplace is set. (Fig. 10)

When a fireplace is installed in a chase or on a
outside wall, enclosure should be treated like
any outside wall in a home. Insulation should be
installed on the inside wall as well as the
outside wall(s). In a chase, it is also a good idea
to install a firestop at the first ceiling level above
the fireplace and enclose the chase with
sheeting material. Insulation may then be
installed above sheeting material to assure the
space around the fireplace is totally protected.
(Fig. 5)

When installing the chimney, DO NOT caulk
between outer pipe and firestop. It is vital that
some air be allowed to flow through this very
thin gap.

CAUTION:  WHEN INSTALLING A FIRE-
PLACE IN AN INSULATED ENCLOSURE, BE
SURE ALL REQUIRED AIR SPACES ARE
MAINTAINED. 
(Fig. 20, Page 14)

Installation

Chimney Supports

The chimney system is supported by the fireplace for
vertical chimney heights less than 30 feet above the
hearth.  Chimney supports are required if the vertical
height exceeds 30 feet with SK8 chimneys or 20 feet
with 3-wall chimneys.  Locate chimney supports at
ceiling holes or other structural framing at 30 foot
(SK8) or 20 foot (3-wall) heights.  Spacing between
chimney supports must not exceed 30 feet(SK8) or 20
foot (3-wall).  Use Chimney Support Model SKCS8.
(Note:  the SKCS8 can not be mounted directly to
the fireplace.) 
 Support provided by elbow straps
fulfills the support requirement only if they are spaced
as previously described. (A chimney support is 2

¹⁄₂

"

long when installed.)

Angled chimney runs require a support every six (6)
feet in addition to the elbow straps. Chimney supports

are used for this function. (Fig. 9)

Chase Installation

A chase is a vertical box-like structure which encloses
the fireplace and/or chimney.  Chases are typically
built on the outside of the house with fireplace opening
cut into the outer wall of a room.  (Fig. 5, Page 5)

If you need help in determining fireplace location or
how the chimney system should be run, contact your
Vermont Castings, Majestic Products dealer for
assistance.

FP284

Fig. 9  Chimney support installation

CHIMNEY
SUPPORT
STRAP

SKCS8

Содержание SC36

Страница 1: ...678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 12345678901234567890123 1234567890123...

Страница 2: ...ings Majestic Products Chimney Top installation instructions Installation other than as instructed by Vermont Castings Majestic Products or Installation and or use of any component part not manufactur...

Страница 3: ...97mm 7 191mm 7 191mm Outside Air Gas Line Access Gas Line Access Electrical Access Recessed Nailing Flange 11 DIA Rough Opening Width 41 Rough Opening Height Rough Opening Depth 3 4 8 7 6 m m 1041mm 1...

Страница 4: ...epth 50 1270mm 50 1270mm 3 6 9 1 4 m m 7 0 1 7 9 1 m m 8 210mm 22 559mm 22 572mm 26 667mm 40 1035mm 14 372mm 15 397mm 9 241mm 3 76mm 8 203mm 7 191mm Outside Air Gas Line Access Electrical Access 1194m...

Страница 5: ...Fireplace and chase parts identification TERMINATION CAP STORM COLLAR PAN FLASHING DRAFTSTOP FIRESTOP STANDOFF NAILING FLANGE GAS LINE ACCESS both sides ELECTRICAL ACCESS OUTSIDE AIR COVER PLATE DAMPE...

Страница 6: ...exit SR SC36 SR SC42 Maximum 90 90 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbo...

Страница 7: ...of the chimney to the peak of the roof is 10 feet or less the top of the chimney must be at least 2 feet above the peak of the roof but never less than 3 feet in height above the highest point where i...

Страница 8: ...A FIRE PLACE IN AN INSULATED ENCLOSURE BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED Fig 20 Page 14 Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney...

Страница 9: ...Remove knockout in the center of the back of the EB1 and install listed cable clamps Feed electrical wire through listed cable clamp leaving approximately six 6 inches of wire exposed through the EB1...

Страница 10: ...pass through ceiling Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used Measure your offset dimension from straight up chimney center point on ceil...

Страница 11: ...t by attaching the first chimney section to the collar on top of the fireplace Install the pipe as pictured in Figure 16 When you get a good lock you will hear the pipe clearly snap together Once sect...

Страница 12: ...lange on the ceiling side and the angled portion extending up into the hole If the area above the ceiling is an attic position the firestop spacer with the flange on the top of the framed hole and the...

Страница 13: ...point of the flue system Drive a nail up through roof at the center point This will determine center point on outside of the roof Cut and Frame Roof Hole Size of roof hole varies with the type of chi...

Страница 14: ...Fig 20 8 Finish Wall Finish the wall with material of your choice Do not install a combustible mantel shelf less than 12 inches above the grille opening If a combustible material is used below a flat...

Страница 15: ...cified for the SP40 Rt must 1 85 minimum Examples of wall shield insulation 1 Manville CERAFORM 126 K 27 1 2 inches thick 2 Majestic EH2416 K 458 1 inch thick required FP531 See mantel drawing for she...

Страница 16: ...rial Factors are related by the formula K 1 R T given thickness R thermal resistance for a given thickness T K thermal conductivity Noncombustible material with a lower R value may be used provided th...

Страница 17: ...new material per inch K of listed material per inch thickness of listed material x Example for Common Brick T new 5 0 0 458 x 0 50 in 5 46 in new required thickness Fig 24 Hearth extension material f...

Страница 18: ...ace side NOTE When installing an ANSI Z21 11 2 ventless appliance the finishing material used for the mantel must be rated at 250 F or greater BTU input of a gas appliance installed in fireplace shoul...

Страница 19: ...2 3030172 8 Screen Clips 7512135 7512135 9 Hearth Pan Cover Plate SC Only 3031104 3031104 10 Outer Collar Assembly SK8 Chimney 3030143 3030143 11 Nailing Flange 2253161 2253161 12 Top Grille Assembly...

Страница 20: ...h action may void the coverage provided by the owner s insurance Glass Door Standard Bi Fold door set Brushed Brass finish 36GDKBB SR C36 42GDKBB SR C42 Black finish 36GDKBK SR C36 42GDKBK SR C42 Poli...

Страница 21: ...ney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low profile pyramid style...

Страница 22: ...Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Chimney...

Страница 23: ...t at a cost to the consumer of Vermont Castings Majestic Products then current list price FOB Vermont Castings Majestic Products factory or pay to the consumer the then current wholesale price of such...

Страница 24: ...c Fireplaces SR SC Series Vermont Castings Majestic Products 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com Vermont Castings Majestic...

Отзывы: