background image

18

NVB Series B-Vent Gas Fireplace

7412950

FP649

• Turn gas supply off

• Turn ON/OFF Switch

  to call for heat. 

NO

NO

NO

NO

NO

NO

NO

Spark across

Ignitor Sensor gap

Power to module

(24V nominal)

YES

YES

YES

YES

YES

YES

YES

• Turn gas on

Pilot burner lights?

Spark stops when pilot 

is lit?

Main Burner lights?

• Replace Module

START

• Line Voltage (120VAC)

• Low Voltage Transformer

  (19.5 minimum VAC)

• ON/OFF Switch

• Wiring connections

• Thermodisk

•  Check continuity of ignition cable and ground wire.

•  Clean flame rod.

•  Check electrical connections beween flame rod and module.

•  Check for cracked ceramic flame rod insulator.

•  Check that pilot flame covers flame rod and is steady blue.

•  Adjust pilot flame.

•  If problem persists, replace module.

Unplug Ignition Lead

and check spark

at module

(24VAC nominal) 

Spark OK?

•  Check ignition cable, ground wiring, Ceramic Insulator and gap. Correct as necessary

•  Check boot of ignition cable for signs of melting or buckling. Take protective

   actions to shield cable and boot from excessive temperatures.

•  Check for 24VAC across MV-MV/PV terminals. If no voltage, replace module.

•  Check electrical connections between module and gas control. If okay, replace gas 

   control or gas control operator.

•  Check for continuity of igniton cable and ground wire. NOTE: If ground is poor or 

   erratic, shutdowns may occur occasionally even though operation is normal

   at time of checkout.

•  Check that the pilot flame covers flame rod and is steady and blue.

•  If checks are okay, replace module.

Troubleshooting

Ends

•  Check that all manual gas valves are open, supply tubing and pressures are good,

   and pilot burner orifice is not blocked.

•  Check electrical connections between module and pilot operator on gas control.

•  Check for 24VAC across PV-MV/PV terminals on module. If voltage is okay, replace

   gas control. If not, replace module.

NOTE: If S8600B goes into lockout, reset system.

NOTE: If S8600B goes into lockout, reset system.

CHECK

 :

System runs until

ON/OFF switch is in

"OFF" position

FP649  Honeywell S8600B T-shoot Guide     5/5/98     

Troubleshooting

Remove glass panel before servicing.

NOVA SIT 822 with Honeywell S8600 B Electronic Ignition

f i r e - p a r t s . c o m

Содержание NVBR36

Страница 1: ...er Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Open windows 2 Do not touch electrical switches 3...

Страница 2: ...ntels 6 Mantel Chart 6 Hearth 6 Insulating for Cold Climates 6 Framing Finishing 7 Final Finishing 7 Gas Speci cations 7 Gas Inlet Manifold Pressures 7 High Elevations 7 Parts Identi cation and Chase...

Страница 3: ...the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appliance must be installed on a metal or wood panel extending the full width and depth of...

Страница 4: ...59mm Recessed Nailing Flange 6 DIA Rough Opening Width 41 Rough Opening Depth 3 76mm 1041mm FP562 Fig 2 NVBC36 Series speci cation and framing dimensions NVBC36 Series Gas Appliance Circulating Model...

Страница 5: ...ssed Nailing Flange 6 DIA Rough Opening Width 47 Rough Opening Depth 3 76mm 35 895mm 1194mm FP564 Fig 4 NVBC42 Series speci cation and framing dimensions NVBC42 Series Gas Appliance Circulating Model...

Страница 6: ...ng F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 mm Black Sur round Face CFM164 CFM170 Fig 5b Combustible mantel leg minimum installati...

Страница 7: ...gnition 30 000 21 500 NVBC36EN Natural Electronic Ignition 30 000 21 500 NVBR36EP Propane Electronic Ignition 30 000 22 000 NVBC36EP Propane Electronic Ignition 30 000 22 000 NVBR42RN Natural Millivol...

Страница 8: ...the appliance location has not been accomplished install the required pipe Consult local plumbing code to assure proper pipe size The gas pipeline can be brought in through the right side of the appl...

Страница 9: ...ide a union so that gas line can be easily disconnected for burner or fan servic ing See gas speci cation for pressure details and ratings NOTE If ex connector is used it must be kept inside of the ap...

Страница 10: ...on excess wire completely within the EB1 Attach the cov erplate to the replace Fig 11 Fig 11 Junction box EB 1 hook up FP580 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Insi...

Страница 11: ...ng configuration Unacceptable venting configuration FP567a Fig 14 Venting con gurations when installing 36GSKBB 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 2 4 6 8 10 12 14 16 18 20 A FP567a Ven...

Страница 12: ...mes with a non ammonia household cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the cir...

Страница 13: ...or units equipped with Hi Lo valves ame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the center of the gas control Flame Characteristics It is important to periodicall...

Страница 14: ...B Series B Vent Gas Fireplace 7412950 LG151 NVB36 log flames 2 2 01 djt Red Glow Embers LG151 Fig 19 NVB36 ame appearance LG150 NVB42 log flames 2 1 01 djt LG150 Fig 20 NVB42 ame appearance fire parts...

Страница 15: ...or turn by hand do not try to repair it call a quali ed service technician Applying force or any attempted repair may result in a re or explo sion D Do not use this replace if any part has been under...

Страница 16: ...h in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re...

Страница 17: ...modisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve Turn to pilot mete...

Страница 18: ...ld cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas control If okay replace gas con...

Страница 19: ...identical to taking care of the Standing Pilot models Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean At least once per year the logs and...

Страница 20: ...3 5 Ceramic Tile single 57803 57803 6a Burner Ori ce Natural Manifold Ori ce 20003532 20003547 6b Burner Ori ce LP Manifold Ori ce 20003541 20003552 7 Thermodisk 20001558 20001558 8 Remote Switch Kit...

Страница 21: ...Assy Natural 4 Way 10002387 10002387 29b E Pilot Assy LP 4 Way 10002388 10002388 30 Sensing Electrodes 57885 57885 31 Ignition Device Honeywell 20000005 20000005 32 Transformer 7522409 7522409 33 Air...

Страница 22: ...Connection The EB 1 electrical junction box is available for use with the fan kits The EB 1 is standard on the electronic igni tion models Glass Doors Bi fold and single panel glass doors are availab...

Страница 23: ...damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation fire parts com...

Отзывы: