NVB Series B-Vent Gas Fireplace

7412950

A.  This heater has a pilot which must be lit manu-

ally.         When lighting the pilot follow these 
instructions exactly.

B.  BEFORE LIGHTING smell all around the 

heater area for gas. Be sure to smell next to 
the floor because some gas is heavier than air 
and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any fireplace
•  Do not touch any electric switch
•  Do not use any phone in your building
•  Immediately call your gas supplier from a 

neighbor's phone.  Follow the gas supplier's 
instructions.

3.  Open control access panel.
4.  Push in gas control knob slightly and turn 

clockwise 

  to "

OFF

".  Do not force.

5.  Close control access panel.

1. 

STOP!

  Read the safety information above.

2.  Turn 

OFF

 all electrical power to the fireplace.

3.  For MN/MP/TN/TP appliances ONLY, go on to 

Step 4. For RN/RP appliances turn the On/Off 
switch to “

OFF

” position or set thermostat to 

lowest level.

4.  Open control access panel.
5.  Push in gas control knob slightly and turn 

clockwise 

  to "

OFF

".

10. Push the control knob all the way in and hold.  

Immediately light the pilot by repeatedly depress-
ing the piezo spark ignitor until a flame appears. 
Continue to hold the control knob in for about one 
(1) minute after the pilot is lit. Release knob and it 
will pop back up. Pilot should remain lit. If it goes 
out, repeat steps 5 through 8.

FOR YOUR SAFETY READ BEFORE LIGHTING

•  If you cannot reach your gas supplier, call the 

Fire Department

C. Use only your hand to push in or turn the gas 

control knob. Never use tools. If the knob will not 
push in or turn by hand, do not try to repair it, call 
a qualified service technician. Applying force or 
any attempted repair may result in a fire or explo-
sion.

D. Do not use this fireplace if any part has been 

under water.  Immediately call a qualified service 
technician to inspect the heater and to replace 
any part of the control system and any gas control 
which has been under water.

To Turn Off Gas to Heater

Lighting and Operating Instructions

1.  Turn the On/Off switch to "

OFF

" position or set 

the thermostat to lowest setting.

2.  Turn off all electric power to the  fireplace if 

service is to be performed.

Lighting Instructions

6.  Wait five (5) minutes to clear out any gas. 

Then smell for gas, including near the floor. If 
you smell gas, 

STOP!

  Follow "B" in the safety 

information above. If you do not smell gas, go 
to the next step.

7.  Remove glass door before lighting pilot. (See 

Glass Frame Removal section).

8.  Visibly locate pilot by the main burner.
9.  Turn knob on gas control counterclockwise 

  to "

PILOT

".

  •    If knob does not pop up when released, stop 

and immediately call your service technician or 
gas supplier.

  •    If after several tries, the pilot will not stay lit, 

turn the gas control knob to "

OFF

" and call your 

service technician or gas supplier.

11. Replace glass door.
12. Turn gas control knob to “

ON

” position.

13. For RN/RP appliances turn the On/Off switch to 

ON

” position or set thermostat to desired setting.

14. Turn on all electrical power to the fireplace.

WARNING:If you do not follow these instructions exactly, a fire or explosion 

may result causing property damage, personal injury or loss of life.

Euro SIT

SIT NOVA

Honeywell

�����

��

���

��

PILOT 

O

FF

 

OFF

 

FP1067

lighting instruction

knobs

3/9/01   djt

5

4

3

2

1

OF

F

Pi

lo

t

3/8" - 1/2"

FP1068

Lighting instructions

Pilots

f i r e - p a r t s . c o m

Содержание NVBR36

Страница 1: ...er Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Open windows 2 Do not touch electrical switches 3...

Страница 2: ...ntels 6 Mantel Chart 6 Hearth 6 Insulating for Cold Climates 6 Framing Finishing 7 Final Finishing 7 Gas Speci cations 7 Gas Inlet Manifold Pressures 7 High Elevations 7 Parts Identi cation and Chase...

Страница 3: ...the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appliance must be installed on a metal or wood panel extending the full width and depth of...

Страница 4: ...59mm Recessed Nailing Flange 6 DIA Rough Opening Width 41 Rough Opening Depth 3 76mm 1041mm FP562 Fig 2 NVBC36 Series speci cation and framing dimensions NVBC36 Series Gas Appliance Circulating Model...

Страница 5: ...ssed Nailing Flange 6 DIA Rough Opening Width 47 Rough Opening Depth 3 76mm 35 895mm 1194mm FP564 Fig 4 NVBC42 Series speci cation and framing dimensions NVBC42 Series Gas Appliance Circulating Model...

Страница 6: ...ng F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 mm Black Sur round Face CFM164 CFM170 Fig 5b Combustible mantel leg minimum installati...

Страница 7: ...gnition 30 000 21 500 NVBC36EN Natural Electronic Ignition 30 000 21 500 NVBR36EP Propane Electronic Ignition 30 000 22 000 NVBC36EP Propane Electronic Ignition 30 000 22 000 NVBR42RN Natural Millivol...

Страница 8: ...the appliance location has not been accomplished install the required pipe Consult local plumbing code to assure proper pipe size The gas pipeline can be brought in through the right side of the appl...

Страница 9: ...ide a union so that gas line can be easily disconnected for burner or fan servic ing See gas speci cation for pressure details and ratings NOTE If ex connector is used it must be kept inside of the ap...

Страница 10: ...on excess wire completely within the EB1 Attach the cov erplate to the replace Fig 11 Fig 11 Junction box EB 1 hook up FP580 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Insi...

Страница 11: ...ng configuration Unacceptable venting configuration FP567a Fig 14 Venting con gurations when installing 36GSKBB 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 2 4 6 8 10 12 14 16 18 20 A FP567a Ven...

Страница 12: ...mes with a non ammonia household cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the cir...

Страница 13: ...or units equipped with Hi Lo valves ame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the center of the gas control Flame Characteristics It is important to periodicall...

Страница 14: ...B Series B Vent Gas Fireplace 7412950 LG151 NVB36 log flames 2 2 01 djt Red Glow Embers LG151 Fig 19 NVB36 ame appearance LG150 NVB42 log flames 2 1 01 djt LG150 Fig 20 NVB42 ame appearance fire parts...

Страница 15: ...or turn by hand do not try to repair it call a quali ed service technician Applying force or any attempted repair may result in a re or explo sion D Do not use this replace if any part has been under...

Страница 16: ...h in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re...

Страница 17: ...modisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve Turn to pilot mete...

Страница 18: ...ld cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas control If okay replace gas con...

Страница 19: ...identical to taking care of the Standing Pilot models Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean At least once per year the logs and...

Страница 20: ...3 5 Ceramic Tile single 57803 57803 6a Burner Ori ce Natural Manifold Ori ce 20003532 20003547 6b Burner Ori ce LP Manifold Ori ce 20003541 20003552 7 Thermodisk 20001558 20001558 8 Remote Switch Kit...

Страница 21: ...Assy Natural 4 Way 10002387 10002387 29b E Pilot Assy LP 4 Way 10002388 10002388 30 Sensing Electrodes 57885 57885 31 Ignition Device Honeywell 20000005 20000005 32 Transformer 7522409 7522409 33 Air...

Страница 22: ...Connection The EB 1 electrical junction box is available for use with the fan kits The EB 1 is standard on the electronic igni tion models Glass Doors Bi fold and single panel glass doors are availab...

Страница 23: ...damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation fire parts com...

Отзывы: