background image

13

NVB Series B-Vent Gas Fireplace

7412950

LG148

NVB42

log set

1/30/01   djt

Left Rear 

Log

Left Cross 

Log

Middle Cross 

Log

Right Cross 

Log

Right Rear 

Log

Ember 

Left Log

Embers

Grate

Lava Rock

Ember 

Right

Fig. 16

  NVB42 log placement.

LG148

Under no circumstances should lava rock 
be placed on any part of the burner assem-
bly.

First Firing

Upon completing the gas line connection, a small 
amount of air will be trapped in the line. When first 
lighting the unit with pilot light, it will take a few minutes 
to purge the trapped air. Once purging is complete, the 
pilot and burner will light and operate as indicated in the 
instruction manual. Subsequent lightings of the appli-
ance will not require purging. 
When lit for the first time, the appliance will emit a slight 
odor for an hour or two. This is due to paint and lubri-
cants used in the manufacturing process.  After each 
lighting, vapor may condense and fog the glass; this 
moisture disappears in a few minutes of burning.

Flame Adjustment

For units equipped with Hi/Lo valves, flame adjustment 
is accomplished by rotating the Hi/Lo adjustment knob 
located near the center of the gas control.

Flame Characteristics

It is important to periodically perform a visual 
check of the pilot and the burner flames. 
Compare them to the illustrations below 
(Figs. 18, 19, 20).  If any of the flames ap-
pear abnormal call a service person.

Inspecting the Venting System

The appliance venting system was designed 
and constructed to develop a positive flow 
adequate to remove flue gases to the out-
side atmosphere.
Any foreign objects in the venting system, 
except those designed specifically for the 
venting system, may cause spillage of flue 
gases (i.e.: carbon monoxide) into the room. 
To inspect the venting system, make sure 
the main gas valve is off. Remove the glass 
panel.  Using a flashlight, check the combus-
tion dome and behind the top grille. Clean if 
necessary.

LO

 

HI

 

Turn 

counterclockwise

to increase 

flame height

Turn clockwise

to lower

flame height

FP390

FLAME ADJUSTMENT KNOB

11/21/96

Fig. 17

  Flame adjustment knob for SIT820 valve.

Fig. 18

  Proper pilot flame height.

FP581

3/8"-1/2"

FP581

NVB-PILOTS

12/4/97

NOVA SIT PILOT

ELECTRONIC

IGNITION

f i r e - p a r t s . c o m

Содержание NVBR36

Страница 1: ...er Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Open windows 2 Do not touch electrical switches 3...

Страница 2: ...ntels 6 Mantel Chart 6 Hearth 6 Insulating for Cold Climates 6 Framing Finishing 7 Final Finishing 7 Gas Speci cations 7 Gas Inlet Manifold Pressures 7 High Elevations 7 Parts Identi cation and Chase...

Страница 3: ...the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appliance must be installed on a metal or wood panel extending the full width and depth of...

Страница 4: ...59mm Recessed Nailing Flange 6 DIA Rough Opening Width 41 Rough Opening Depth 3 76mm 1041mm FP562 Fig 2 NVBC36 Series speci cation and framing dimensions NVBC36 Series Gas Appliance Circulating Model...

Страница 5: ...ssed Nailing Flange 6 DIA Rough Opening Width 47 Rough Opening Depth 3 76mm 35 895mm 1194mm FP564 Fig 4 NVBC42 Series speci cation and framing dimensions NVBC42 Series Gas Appliance Circulating Model...

Страница 6: ...ng F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 mm Black Sur round Face CFM164 CFM170 Fig 5b Combustible mantel leg minimum installati...

Страница 7: ...gnition 30 000 21 500 NVBC36EN Natural Electronic Ignition 30 000 21 500 NVBR36EP Propane Electronic Ignition 30 000 22 000 NVBC36EP Propane Electronic Ignition 30 000 22 000 NVBR42RN Natural Millivol...

Страница 8: ...the appliance location has not been accomplished install the required pipe Consult local plumbing code to assure proper pipe size The gas pipeline can be brought in through the right side of the appl...

Страница 9: ...ide a union so that gas line can be easily disconnected for burner or fan servic ing See gas speci cation for pressure details and ratings NOTE If ex connector is used it must be kept inside of the ap...

Страница 10: ...on excess wire completely within the EB1 Attach the cov erplate to the replace Fig 11 Fig 11 Junction box EB 1 hook up FP580 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Insi...

Страница 11: ...ng configuration Unacceptable venting configuration FP567a Fig 14 Venting con gurations when installing 36GSKBB 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 2 4 6 8 10 12 14 16 18 20 A FP567a Ven...

Страница 12: ...mes with a non ammonia household cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the cir...

Страница 13: ...or units equipped with Hi Lo valves ame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the center of the gas control Flame Characteristics It is important to periodicall...

Страница 14: ...B Series B Vent Gas Fireplace 7412950 LG151 NVB36 log flames 2 2 01 djt Red Glow Embers LG151 Fig 19 NVB36 ame appearance LG150 NVB42 log flames 2 1 01 djt LG150 Fig 20 NVB42 ame appearance fire parts...

Страница 15: ...or turn by hand do not try to repair it call a quali ed service technician Applying force or any attempted repair may result in a re or explo sion D Do not use this replace if any part has been under...

Страница 16: ...h in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re...

Страница 17: ...modisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve Turn to pilot mete...

Страница 18: ...ld cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas control If okay replace gas con...

Страница 19: ...identical to taking care of the Standing Pilot models Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean At least once per year the logs and...

Страница 20: ...3 5 Ceramic Tile single 57803 57803 6a Burner Ori ce Natural Manifold Ori ce 20003532 20003547 6b Burner Ori ce LP Manifold Ori ce 20003541 20003552 7 Thermodisk 20001558 20001558 8 Remote Switch Kit...

Страница 21: ...Assy Natural 4 Way 10002387 10002387 29b E Pilot Assy LP 4 Way 10002388 10002388 30 Sensing Electrodes 57885 57885 31 Ignition Device Honeywell 20000005 20000005 32 Transformer 7522409 7522409 33 Air...

Страница 22: ...Connection The EB 1 electrical junction box is available for use with the fan kits The EB 1 is standard on the electronic igni tion models Glass Doors Bi fold and single panel glass doors are availab...

Страница 23: ...damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation fire parts com...

Отзывы: